This article is part of the series on power cuts in Sweden. The overview of all topics – including heating, water, medical devices, animals and a decision guide per household – is in the complete guide to power cuts in Sweden.
Contents
- What MCF (formerly MSB) recommends – as of October 2026
- Step zero: a power inventory of your home
- Heating: heat pump, wood stove, backup heaters, CO alarms
- Water: mains supply, well pump, pressure tank, frost protection
- Light
- Cooking without power – with a fuel calculation
- Fridge and freezer: how long do they last?
- Information: radio, VMA, SE-Alert, 113 13
- Communication: mobile, fibre, a family plan
- Cash and card payments without a network
- Important documents: digital, offline, encrypted
- Medicines, refrigeration and medical devices
- Pets and livestock
- Five typical households – what matters in each
- Printable checklists
- The annual test plan
- After the outage: restart, compensation, review
- Common mistakes
- What I learned from my own system
1. What MCF (formerly MSB) recommends – as of October 2026
First, a correction many guides have not caught up with: the Swedish Civil Contingencies Agency (MSB) became the Swedish Civil Defence and Resilience Agency – Myndigheten för civilt försvar (MCF) – on 1 January 2026, and its website moved from msb.se to mcf.se. Old msb.se links often no longer work. The advice is largely unchanged, but the home preparedness pages were reviewed in autumn 2026 (marked “senast granskad” 1 and 19 October 2026).
The brochure “Om krisen eller kriget kommer” (“In case of crisis or war”) was posted to every household in November 2024. It is still the current edition – there is no new household edition for 2026 (as of October 2026). It is available digitally, as audio, in easy Swedish, sign language and braille, and in many languages including English. A separate version for businesses is new.
The core: at least one week
MCF puts the goal simply: everyone who can should manage at least seven days with food, water, radio and heat. The reasoning is practical – if most households cope on their own for a week, society can focus on those who cannot. The “72 hours” you often see comes from the US and Canada. Sweden has recommended a week since a government defence decision in 2020, and since 2024 the wording is “at least a week”. As MCF says itself, though: 72 hours is better than nothing.
What MCF says can happen
The list is surprisingly technical: the heating stops. Cooking and storing food becomes difficult. No water comes out of the tap or the toilet. You cannot refuel. Cards and cash machines do not work. Mobile networks and the internet go down. Medicines and medical equipment become hard to get. Almost every item depends on electricity – which is where this guide starts.
What changed in 2026
- SE-Alert: Since July 2026, public warnings (VMA) can be sent by cell broadcast straight to mobile phones in an area – no app, no registration. The first test ran in Stockholm and Gotland counties on 7 September 2026.
- Offline card payments: From 1 July 2026 you should be able to pay by card for essentials (food, medicine, fuel) even when data communication is disrupted – with your PIN.
- Copper network: According to MCF, the copper telephone network is being switched off during 2026. The old landline that kept working in a power cut is no longer a fallback.
- Medicines: The National Board of Health and Welfare (Socialstyrelsen) recommends that people on long-term prescription medicines keep one month’s supply at home.
The MCF basics – and the technical question behind each
| MCF recommendation | The technical question | Section |
|---|---|---|
| Radio running on batteries, wind-up or solar | Which station and frequency? How long do batteries last in the cold? | 8 |
| Torch and head torch, spare batteries | Which battery chemistry works at −20 °C? | 5 |
| Bottles and containers of water | How much exactly – and what about a private well? | 4 |
| Food that needs no fridge, camping stove | How much fuel for a week? | 6 |
| Alternative heat source | What works without power, what needs ventilation, where does the CO alarm go? | 3 |
| Power banks, spare batteries | How many phone charges are really inside? | 9 |
| Cash | What works at the till without a network? | 10 |
| Phone numbers on paper | Plus: documents offline and encrypted | 11 |
| First aid kit, medicines | Refrigerated medicines, powered devices | 12 |
MCF sells nothing and recommends no brands. Neither do I – this article has no affiliate links. Where I quote power figures they are typical values or clearly marked assumptions in worked examples. For your own equipment the rating plate always applies.
2. Step zero: a power inventory of your home
Before you buy anything, you need an answer to one question: what in my home stops working when the power goes? The list is almost always longer than expected. Typical surprises:
- The wood stove heats – but the water-based heating system it is connected to needs a circulation pump.
- The pellet boiler needs power for ignition, fan and feed screw.
- District heating reaches the house, but the circulation pump inside – and often pumps in the network – need electricity.
- A drilled well delivers water only while there is pressure in the pressure tank (Swedish “hydrofor”) – often a few dozen litres.
- A sewage pump station (common in Sweden where there is no gravity fall to the mains) or a small treatment plant stops pumping. Keep flushing and it can back up.
- The garage door, electric lock, burglar alarm, an elderly relative’s personal alarm.
- The fibre media converter and router – without them no Wi-Fi calling, no cameras, no smart home.
How to do the inventory in 30 minutes
- Walk through every room, including the basement, boiler room, garage, well house and outbuildings. Note every device with a plug or fixed connection.
- Mark each device: critical (heat, water, medical, animals), important (fridge/freezer, communication) or can wait.
- Copy the power rating from the plate (watts, or amps × 230 V). For motors (pumps, compressors) also note: motor = high starting current.
- In the fuse board, note which circuit feeds the critical devices. You will need this for a generator and for the test.
- For devices with varying load (freezer, heat pump), measure for a few days with a plug-in energy meter or a smart plug with metering. The 24-hour average matters more for planning than the peak.
Typical power figures – for orientation
The table shows the orders of magnitude usually found on rating plates of common household equipment. Yours may differ considerably; your plate or your measurement is what counts.
| Device | Typical running power | Start-up | Note |
|---|---|---|---|
| Heating circulation pump | 5–60 W (modern high-efficiency pumps at the low end) | low | Smallest but often most important load |
| Fridge-freezer | annual consumption from the EU label ÷ 365, often 0.4–0.8 kWh/day | compressor: several times rated current | Cycles on and off |
| Submersible pump, drilled well | often 0.5–1.5 kW | several times rated current | Often three-phase (400 V) – then a small generator will not do |
| Router + fibre box | 10–25 W together | – | |
| LED bulb | 3–10 W | – | |
| Air-to-air heat pump | see rating plate, strongly load-dependent | inverter units start softly | No heat without power |
| Kettle | 1.8–2.2 kW | – | Short but high peak |
| CPAP machine | per manufacturer, considerably more with humidifier | – | Discuss with your prescriber |
This list gives you your energy budget: the sum of critical loads in watt-hours per day. That is the number against which you judge any backup solution – power station, generator or home battery.
Worked example (assumptions, not measurements): circulation pump 25 W × 24 h = 600 Wh. Fridge-freezer 0.6 kWh = 600 Wh. Router and fibre box 20 W × 24 h = 480 Wh. Two LED lamps 2 × 6 W × 6 h = 72 Wh. Charging two phones 2 × 15 Wh = 30 Wh. Total: about 1.8 kWh per day – without heating and without the well pump. A 1 kW well pump running 20 minutes a day in total adds about 330 Wh. Heating itself (direct electric, heat pump) is almost always the item that breaks any small backup solution – so it gets its own section.
3. Heating: heat pump, wood stove, backup heaters, CO alarms
In a Västernorrland winter, heat is the question everything hangs on. MCF says a home gets cold quickly in a winter power cut. How quickly, the Swedish Energy Agency (Energimyndigheten) has calculated for twelve typical Swedish houses.
How fast does your house get cold?
| House type (Energimyndigheten) | Heating | Indoors after 24 h without power at −10 °C | +5 °C reached at −20 °C after |
|---|---|---|---|
| Old log house, 1880 | Wood boiler | 3.9 °C | just under 1 day |
| 1930s house | Oil | 6.5 °C | 1 day |
| Brick villa, 1972 | District heating | 8.7 °C | – |
| Small house, 1950 | Pellet boiler | 8.8 °C | just over 1 day |
| Link house, 1975 | Direct electric | 10 °C | just over 1 day |
| Bungalow, 1988 | Water-based electric | 10 °C | just under 2 days |
| Terraced house, 2005 | Exhaust-air heat pump | 13.1 °C | 2 days |
| Low-energy villa, 2007 | District heating | about 14–16 °C | 4 days |
The lesson: in hard frost an older, poorly insulated house drops to +5 °C within a day. At that point the risk is not just cold feet but frozen pipes. A modern house gives you a few days. Both are shorter than a week – without a heat source that works off-grid, MCF’s one-week target does not add up in winter.
Which heating works without power?
| System | Works without power? | What it needs |
|---|---|---|
| Direct electric radiators | No | A large generator for the whole house – rarely sensible in practice |
| Air-to-water and ground-source heat pump | No | Compressor, pumps, controls; the electric immersion heater draws several kW in backup mode |
| Air-to-air heat pump | No | Can run on a generator or home battery if output and start-up match |
| Exhaust-air heat pump | No | As above, often with immersion heater |
| Pellet or oil boiler | No | Ignition, fan, screw/burner, circulation pump – usually a few hundred watts, more at ignition |
| District heating | Partly | The circulation pump in the house; whether the network keeps delivering depends on the supplier |
| Wood boiler with water circuit | Risky without pump | Without the circulation pump it can overheat – follow the manufacturer’s instructions |
| Wood stove, tiled stove, open fireplace | Yes | Wood, a working chimney, ventilation |
| LPG or paraffin heater | Yes | Fuel, ventilation, CO alarm |
The heat pump without power – what actually works
Plainly: a heat pump produces no heat at all without electricity. It is an electrical machine that uses one kilowatt-hour of electricity to move several kilowatt-hours of heat from air, ground or water. That efficiency is exactly what makes it interesting for backup power: an air-to-air heat pump keeping one room warm uses far less electricity than an electric heater delivering the same heat.
Worked example (assumptions): a living room needs 1.5 kW of heat continuously at −15 °C outside. Assume the air-to-air heat pump has a coefficient of performance (COP) of 2 at that temperature. Electrical input: 1.5 kW ÷ 2 = 0.75 kW. Over 24 hours: 18 kWh. An electric heater would need 36 kWh for the same heat. A generator with 2–3 kW continuous output can carry the heat pump; a typical 1–2 kWh power station only for a few hours.
For a heat pump to run on a generator or home battery, three things must be right:
- Connection: heat pumps are hard-wired; you cannot plug them into a generator socket. A changeover switch or prepared connection point must be installed by an authorised electrician, who also notifies the grid operator. Back-feeding into the grid must be impossible – otherwise you endanger the crews repairing the line.
- Output: the rating plate gives the maximum input. The generator must supply that continuously, with a margin. On air-to-water and ground-source heat pumps, switch off the immersion heater in backup mode (in the menu), or the system can suddenly draw several times more.
- Power quality: Energimyndigheten points out that sensitive electronics need an inverter generator. Modern heat pumps are full of electronics.
Whether a home battery with a hybrid inverter keeps running in a grid outage is a separate question – many systems shut down for safety when the grid disappears and need a dedicated backup function. That depends on the equipment; what it takes is covered in detail in Backup power for home and cabin. Whether a home battery pays off at all is discussed in the case study of a price-controlled home battery.
Wood stove and tiled stove: the best insurance
A working wood stove, tiled stove (kakelugn) or open fireplace is, according to both Energimyndigheten and MCF, the most important backup heat. To make sure it works when it matters:
- Chimney sweep and fire safety inspection: chimney fires are doubly dangerous when the fire service is stretched. Energimyndigheten explicitly warns about overheating chimneys if you burn more than the stove is designed for.
- Calculate a week of firewood: rule of thumb: air-dried wood yields about 4 kWh per kilogram. A stove with 70 % efficiency turns that into roughly 2.8 kWh of heat. Heating one room at 1.5 kW for ten hours a day needs 15 kWh, so about 5–6 kg of wood a day and 35–40 kg a week. For the whole house around the clock, many times more. Store it dry – damp wood gives much less and sooty.
- Matches and firelighters in a fixed place, not in the woodshed at the far end of the plot.
- Not while sleeping (MCF): no stove, no candles, no heater while everyone is asleep.
Backup heaters running on LPG or paraffin
Portable LPG (gasol) and paraffin heaters are listed by MCF as an alternative heat source. They heat a room, not a house. The rules in the manual are not a formality: clearance from combustibles, ventilation, only the approved fuel, never refill while hot. Energimyndigheten is specific: keep LPG cylinders upright in storage, use and transport; when switching off, close the cylinder valve first and then the heater valve; check hoses and seals regularly. Storage of LPG at home is governed by the regulations MSBFS 2020:1.
Any flueless heater consumes oxygen from the room and releases combustion gases into it. That is why MCF says: ventilate regularly – even if it feels wrong to let the heat out. A short, wide-open airing loses less heat than a window left ajar all the time.
Carbon monoxide alarm: the cheapest life insurance in the house
Carbon monoxide (CO) is odourless and forms in any incomplete combustion – a stove with poor draught, an LPG heater, a barbecue, a generator. The Swedish Medical Products Agency and the Poisons Information Centre reported a record number of CO poisonings needing hospital care in 2022, typically caused by barbecues and LPG heaters indoors and by burning wood incorrectly. A winter power cut is exactly when people do this.
- Which alarm: a carbon monoxide alarm to EN 50291, battery-powered (a mains alarm is useless in a power cut unless it has a backup battery). A smoke alarm does not detect CO, and a CO alarm does not detect smoke – you need both.
- Where: in the room with the stove or heater and in every bedroom, following the manufacturer (usually wall-mounted, not directly above the stove).
- Test: press the test button monthly, change batteries as instructed and replace the unit after the stated lifetime (the sensor ages).
- Generator: a generator belongs outdoors, always, away from windows, doors and vents – never in a garage, cellar, shed or under a porch roof. Not even “just for a bit”.
If you suspect CO poisoning (headache, dizziness, nausea in several people at once): get outside immediately and call 112.
One room, many layers
MCF advises gathering in one room: blankets over the windows, rugs on the floor, gaps sealed (keep the escape route clear), layers of clothing with wool next to the skin, sleeping bags, everyone sleeping in the same room, even a den under the table made of blankets. Technically you are shrinking the volume you need to heat – which is what makes small heat sources effective at all. Choose the room in advance: ideally the one with the stove, or an inner room with little external wall and small windows.
Frost protection for the pipes
Once the house drops below +5 °C, pipes along external walls, in the crawl space and in the loft are at risk. MCF: insulate pipes, and never thaw an ice plug with a naked flame – turn off the water and call a plumber and your insurer.
- Heating cables on pipes and the well pipe need power themselves – they fail exactly when needed.
- Do you know where the main stopcock is? Does it turn? Many have not been touched in years.
- In a long outage in a house you cannot keep warm: turn off the water and drain the pipes (drain valves, lowest point). Write down the sequence for your house – with photos of the valves. For holiday homes this is routine anyway.
- A temperature sensor with alarm (mobile network, own battery) warns you when a cabin or plant room drops below +5 °C. See Holiday home in Sweden: monitoring and internet.
4. Water: mains supply, well pump, pressure tank, frost protection
MCF is clear: lack of water is far more serious than lack of food. Allow three to five litres per adult per day for drinking, cooking and basic hygiene, plus pets.
| Household | 1 day | 3 days | 7 days |
|---|---|---|---|
| 1 person | 3–5 l | 9–15 l | 21–35 l |
| 2 people | 6–10 l | 18–30 l | 42–70 l |
| 4 people | 12–20 l | 36–60 l | 84–140 l |
140 litres is seven 20-litre containers – more than most households can store. MCF itself says a little is better than nothing. So the strategy is staged: a basic supply for the first days, plus a plan for getting water after that.
Mains water: why it stops “after a while”
The municipal network has reservoirs and backup power at key points, but pumps and treatment need electricity. MCF writes that water pumps may stop working after a while when the power goes. If you live high up or at the end of a line you notice first. So:
- As soon as a long outage looks likely (storm warning, the grid operator announces several hours), fill containers, pans and – if clean – the bath. Bath water is for flushing and washing, not drinking.
- The municipality may set up water tanks but will only hand out limited amounts. You need your own containers: jerrycans with a tap, buckets with lids.
Storing water: PET bottles in the freezer
The neatest tip from MCF and the Swedish Food Agency (Livsmedelsverket) doubles as a cooling trick: fill PET bottles with tap water (not to the top, or they split) and freeze them. They are a water reserve and ice packs in one: in a power cut they keep the freezer cold longer, later they go into the fridge, and finally you drink them. Store containers dark and cool, check them once or twice a year (look, smell, taste) and replace as needed – the old water goes on the plants.
Private well: the underestimated problem
Many rural homes in Västernorrland have their own well, usually drilled, with a submersible pump. MCF and Livsmedelsverket agree: a private well is unaffected by disruption to the municipal supply – but you are responsible, and without power no water comes up. Make a plan: bucket, hand pump or backup generator.
How the system works
The pump sits deep in the borehole and pushes water into a pressure tank, usually in the basement or plant room. A pressure switch starts the pump when the pressure falls below one value and stops it at the upper value. The tank only buffers part of its nominal volume: in a membrane tank, the usable volume between cut-in and cut-out pressure is typically only a fraction of the size printed on it. In practice: after the power fails you get a few litres from the tap, then nothing.
Three ways to get well water in an outage
| Solution | Advantage | Catch |
|---|---|---|
| Bucket on a rope (dug well) | Cheap, no power | Impossible in a drilled well with a 10–15 cm casing; hygiene |
| Hand pump | No power, permanent | Suction pumps only manage shallow depths; deep drilled wells need special piston pumps fitted alongside the submersible – ask a well driller |
| Generator for the well pump | Normal pressure in the house | Starting current; often 400 V; fixed connection only by an electrician |
Well pump on a generator – what matters
- Phases: if the pump plate or control box says 3×400 V, an ordinary 230 V generator will not do. You need a 400 V generator (for example tractor-driven, as Energimyndigheten mentions) or another solution.
- Starting current: a pump motor draws several times its rated current when starting. Size the generator for the start, not just the rated output – otherwise the voltage collapses and the pump fails to start or is damaged. Well pump manufacturers note that generator operation may require different sizing.
- Run in blocks: do not let the generator start for every litre. Start it, fill the pressure tank and containers, switch off. A few running hours a day is then enough.
- Connection: the well pump is almost always hard-wired. An authorised electrician can fit a changeover switch or inlet for that one circuit. A manageable job – but not DIY.
Afterwards: water test
MCF and Livsmedelsverket recommend having your water tested after events such as power cuts, floods or nearby accidents. Boiling kills bacteria but does not remove chemical contamination.
Do not forget the sewage
If your waste water relies on a pump (pump station, aerated treatment plant), it stops flowing in a power cut. The pump chamber fills until it backs up. Ask the municipality or manufacturer how much buffer your system has, and flush only when necessary. The pump station can – connected by an electrician – be an important candidate for the generator.
5. Light
MCF recommends torches and head torches with spare batteries, candles, tea lights and a paraffin lamp. Three points are technically interesting.
Battery chemistry and cold
- Alkaline batteries (ordinary AA/AAA) lose a lot of capacity in the cold. For lamps kept in a cold cabin, the car or a shed, lithium primary batteries (AA/AAA “Lithium”, non-rechargeable) are far more cold-tolerant and store for years.
- Low self-discharge NiMH rechargeables (often sold as “pre-charged”) are good if you top them up regularly. Ordinary NiMH are half empty after a few months in a drawer.
- Do not store batteries inside devices – leaking cells ruin the contacts.
A power bank as a light source
MCF quotes a young woman in Kyiv who runs her desk lamp from a power bank via USB. That is efficient: a 10,000 mAh power bank holds about 37 Wh at a cell voltage of 3.7 V. After conversion losses (around 20 %) about 30 Wh remain. A 2 W USB LED lamp then runs for roughly 15 hours – several evenings.
Candles and paraffin
Candles and tea lights give a little light and a little warmth but are the most common cause of fire during outages. MCF: space tea lights apart, on a non-combustible base or in a dish of water, never while sleeping. Paraffin lamps need ventilation. A fire extinguisher and fire blanket are on MCF’s heating list – check the pressure gauge once a year.
6. Cooking without power – with a fuel calculation
Induction hob, cooker, oven, microwave and kettle are dead. MCF recommends a spirit or camping stove, ideally outdoors, and the barbecue. Indoors: the stove stable and level on a non-combustible surface, clear of cupboards and the extractor hood, with a way to put out a fire within reach.
How much fuel do I need for a week?
Most of the energy in off-grid cooking goes into boiling water (tea, coffee, pasta, dried food, boiling well or lake water). So it is easiest to calculate in “litres of boiled water”.
- Physics: heating 1 litre of water from 10 °C to 100 °C takes 4.19 kJ/(kg·K) × 1 kg × 90 K ≈ 377 kJ ≈ 0.105 kWh.
- Efficiency: an open stove outdoors loses a lot of heat. With a windshield and lid, 30–50 % is realistic. So 1 litre of boiled water needs 0.2–0.35 kWh of fuel energy.
- Fuel: LPG (propane/butane) contains about 12.8 kWh per kilogram. One kilogram is enough for roughly 35–60 litres of boiled water.
- Demand: suppose a household of four boils 6 litres a day (drinks, food, some water treatment): 42 litres a week, so about 1 kg of LPG a week just for water. With cooking and a margin: 2–3 kg – one small cylinder.
The calculation shows two things: cooking is manageable if you have a stove and a full cylinder. And if you have to boil well or lake water, demand doubles quickly. Choose food that cooks fast, needs little water or can be eaten cold – exactly MCF’s advice.
What about a power station?
A kettle needs about 0.12 kWh per litre (it is very efficient). A power station with 1 kWh of usable capacity could boil about eight litres – provided its inverter delivers 2 kW. It works, but it wastes a scarce resource you would rather use for cooling, communication and light.
7. Fridge and freezer: how long do they last?
One of the most common questions – and online answers vary widely. Here are the reliable ones.
Fridge: 4 or 7 hours
Livsmedelsverket’s fact sheet on power cuts and food in the fridge (October 2025) gives a clear rule: you can judge fridge food by looking, smelling and possibly tasting if the outage lasted
- no more than 7 hours and the fridge was at 4 °C beforehand,
- no more than 4 hours if it was at 8 °C.
That leads to a very simple technical measure: set your fridge to 4 °C (many run warmer) and put a thermometer that needs no power inside. Note the time when the power goes, open the door as little as possible, and add frozen water bottles or ice packs. MCF adds: eat what is in the fridge first.
Freezer: “a couple of days” – but only under conditions
MCF writes that a freezer stays cold enough for a couple of days even when the power is off – as long as you open it as little as possible. Manufacturers are more cautious: one large manufacturer states 10–18 hours for its upright freezers and refers to the manual for your specific model. That figure (“storage time in case of power failure”) is in your appliance’s product sheet or manual – look it up today, not during the outage.
What extends the time follows from physics:
- Full beats half-empty. Frozen mass stores cold; air does not. Fill gaps with frozen water bottles (the MCF trick).
- Chest beats upright. Opening a chest freezer does not let the cold air fall out.
- Cold location: a chest freezer in a cold basement or shed lasts longer than one in a warm kitchen.
- Cover it: blankets or sleeping bags on top (clear the compressor vents again when power returns).
- Use the winter: in frost, frozen food can be kept in closed boxes on the balcony, deck or in an unheated shed (MCF, Energimyndigheten) – protected from sun and animals.
Running fridge and freezer on backup power
If you want to keep cooling going on a power station or generator, use the annual consumption on the EU energy label: divided by 365 it gives the average daily need. 220 kWh/year is about 0.6 kWh per day. A power station with 1 kWh usable capacity covers that for just over a day. Smarter is not to run the freezer continuously but twice a day for a few hours: that holds the temperature and spares the battery. Important: the compressor draws several times its running power on start – the inverter must handle that peak.
After the outage: thaw or refreeze?
Frozen food that still has ice crystals or feels fridge-cold can generally be used – when in doubt it depends on the food. Raw meat, fish and ready meals that have fully thawed and warmed up should not be refrozen but thrown away. Livsmedelsverket has detailed guidance. A freezer thermometer with min/max or a battery-powered wireless sensor shows you afterwards how warm it really got.
8. Information: radio, VMA, SE-Alert, 113 13
Sveriges Radio P4 is the emergency channel
MCF: Sveriges Radio P4 keeps broadcasting in crisis and war, with the situation, local weather forecasts, where to get water and whether evacuation is under way. There is no special “emergency radio” you need to buy – any radio that works without mains power and receives P4 will do: batteries, solar, wind-up or car radio.
- Note the frequency in advance: write the FM frequency of P4 for your area on the sheet in your emergency box. Teracom publishes frequency tables for all stations.
- FM or DAB+? P4 can be received on FM nationwide. A radio that does both is ideal; I would not rely on a DAB+-only set as the sole emergency radio.
- Wind-up radios: handy, but the built-in batteries are small. Test how long a minute of winding lasts. A radio that also takes AA batteries is the more robust choice.
- Car radio: works but drains the starter battery. And: never run the engine in a closed garage to charge it.
VMA, Hesa Fredrik and SE-Alert
VMA (“important public announcement”) is Sweden’s warning system. It consists of the outdoor siren nicknamed Hesa Fredrik, announcements on radio and TV, text messages, internet and apps – and since July 2026 SE-Alert.
- Hesa Fredrik is tested at 15:00 on the first non-holiday Monday of March, June, September and December. The warning signal: 7 seconds of tone, 14 seconds of silence, repeated. All clear: a continuous 30-second tone. On a warning: go indoors, close doors and windows, turn off ventilation if possible, listen to P4.
- SE-Alert uses cell broadcast: the warning goes to every phone connected to masts in a given area – including foreign phones, with no registration. Most iPhones and Android phones with 4G/5G support it. Check the technology: your phone settings have a section for emergency alerts (depending on the model under “Notifications” or “Safety and emergency”). Leave the alerts switched on. Older phones and simple senior phones are worth checking on a test date.
- SE-Alert only works while the mobile network in your cell is up. It does not replace the radio.
113 13, krisinformation.se and your grid operator
- 113 13 is Sweden’s national information number for serious accidents and crises – verified information, and you can report what you see. 112 remains for emergencies.
- krisinformation.se collects information from all authorities, also as an app where you choose the counties (län) you follow. Some content is available in English.
- Your grid operator (elnätsbolag) reports faults and estimated restoration times – many offer a text message service. Sign up today. The same goes for your water supplier.
- Trygghetspunkter (municipal support points): during major disruptions, municipalities open staffed locations offering information, warmth, drinking water and phone charging, for example in schools or churches. Find out in advance where they are in your municipality.
9. Communication: mobile, fibre, a family plan
What lasts how long
The mobile network has backup power – but limited. The Swedish Post and Telecom Authority (PTS) regulation in force until January 2026 required backup power for mobile coverage of at least one hour in towns of more than 8,000 inhabitants and four hours elsewhere; it was repealed with the new cybersecurity act and successor rules have been announced. For planning purposes: expect the mobile network to weaken or fail after some hours in a long outage.
Your own fibre connection works exactly as long as your fibre box and router have power – zero seconds without a UPS. How long router, cameras and phone last on which battery is worked out step by step in Power cut: how long do router, cameras and phone keep running? Whether the fibre network outside keeps working depends on the operator. What a second connection can do for you is shown in the off-grid cabin case study, which uses redundant mobile links.
When your own network fails
- Another operator’s network may still work. MCF: ask whether you can borrow someone else’s phone.
- National roaming during heightened alert: Telia, Tele2, Telenor and Tre have prepared so customers can switch manually to another network. It is only activated during heightened alert (höjd beredskap). Practise once where manual network selection is on your phone.
- If you cannot reach 112: go to the nearest fire station, which has an emergency phone.
- The copper network is being switched off in 2026. If you had a landline that worked in power cuts, that fallback is gone.
Power for your phone: how many charges are in a power bank?
A typical smartphone battery holds 12–20 Wh. The figure on a power bank (mAh) refers to the cell voltage of 3.6–3.7 V. For a 20,000 mAh power bank: 20 Ah × 3.7 V = 74 Wh. After conversion and charging losses often only 60–70 % reaches the phone, so 45–50 Wh. That is about three charges of a 15 Wh phone – not the “six” you get by naively dividing 20,000 by 3,000 mAh.
- Cold: lithium batteries deliver less in the cold and should not be charged below 0 °C. Keep power banks on your body or in the warm room.
- Self-discharge: recharge power banks every three to six months (it is in the test plan below).
- Save the phone: low-power mode, dim screen, mobile data off if you only need to be reachable. Text messages often get through on an overloaded network when calls fail.
- Car charger (12 V) is on MCF’s list. But again: engine running outdoors only.
The family communication plan
Technology does not replace an agreement. Decide – and write it down:
- A meeting point if you cannot reach each other (MCF’s advice), plus a fallback.
- Time windows: for example, everyone switches on their phone for ten minutes on the hour. It saves battery and everyone knows when to try.
- Who collects the children from school or nursery? Who checks on neighbours or elderly relatives?
- A phone list on paper: family, neighbours, health centre, municipality, fire service, grid operator, water supplier, insurer, vet. Your phone’s contacts are useless with a flat battery.
Staying reachable without power and fibre (mobile routers, two-way radio, satellite, phone battery strategy) is covered in Staying reachable in a power cut.
10. Cash and card payments without a network
Sweden is nearly cashless – and therefore vulnerable. MCF and the Riksbank recommend:
- SEK 1,000 in cash per adult, preferably in mixed denominations, intended to cover a week of essential purchases. Keep it with your passport and important papers so you can find it.
- Use cash now and then – so you recognise the notes and the system stays in use.
- Getting cash: cash machines (max. 30 notes per withdrawal), rounding up a card payment in shops that handle cash, bureaux de change, or ordering via your online bank for delivery to a parcel point.
What works at the till without a network?
| Method | Shop has no power | Shop has power but no data connection |
|---|---|---|
| Cash | Yes, if the shop accepts cash (it may refuse) | Yes |
| Card with PIN | No | From 1 July 2026: intended to work offline for food, medicine, fuel |
| Contactless tap | No | Uncertain – a PIN may be required |
| Swish, BankID | No | No (needs internet at your end and the bank’s) |
| Fuel station pump | No – pumps need power | Depends on the station |
Technical homework:
- Do you know your card PINs? Many people have not used them in years. Offline payments need them.
- Two card networks (Visa and Mastercard), ideally accounts at two banks.
- Two ways to identify yourself electronically: besides Mobile BankID, for example a security token or card reader from your bank. MCF explicitly recommends several ID methods and several internet connections.
- Keep the tank full: sensible in winter anyway. Half a tank as a minimum is a good rule.
11. Important documents: digital, offline, encrypted
MCF recommends keeping cash with your passport and important documents, and a phone list on paper. I add a digital copy that works without internet – your cloud is out of reach during an outage, and after a fire or flood the paper copies may be gone.
What to include
- Passport, ID card, driving licence (both sides), personal number certificate (personbevis), residence permit
- Insurance policies with the claims phone number, title deed (lagfart) or tenancy agreement
- Medication list with active ingredient and dose, prescription overview, vaccinations, allergies
- Bank details and card blocking numbers
- Pet passports and vaccination records
- Manuals and emergency operating instructions for heating, heat pump, well pump, generator and stove (as PDF – there is no internet to look things up during an outage)
- Photos or a video of your home and valuables for insurance
- The “turn off and drain the water” plan with photos of the valves
How to build the offline copy
- Everything as PDF or JPG in one folder – no unusual formats that need an app.
- On an encrypted USB stick (for example with BitLocker To Go on Windows, or an encrypted container another computer can also open). Encryption is mandatory: the stick holds everything an identity thief needs.
- Password: use three or four easy-to-remember words that have nothing to do with each other, separated by full stops – for example
Ladder.Kettle.Harbor.Pencil. It is long enough and can be read out over the phone to a family member in an emergency, which is practically impossible with a random jumble of characters. - Two copies: one at home with the papers, one elsewhere (with relatives, in a safe deposit box, at the holiday home).
- The most important documents also as offline files on your phone (mark them as available offline). Check in flight mode that they really open.
- Update once a year (test plan).
12. Medicines, refrigeration and medical devices
A month’s supply
For food the rule is one week – for long-term prescription medicines Socialstyrelsen recommends one month’s supply: for high blood pressure, heart disease, asthma/COPD, gastrointestinal and kidney disease, diabetes, and also for prescribed consumables such as blood glucose testing supplies. Exceptions include medicines dispensed in dose bags, certain controlled drugs and products that cannot be stored. Rotate like your pantry: oldest first.
Medicines that must be kept cold
Insulin, some eye drops, biologics and vaccines should be refrigerated. For many insulins, an opened pen may be kept at room temperature for a limited time according to the product information – often a few weeks, but it varies by product. Read the leaflet now and write the permitted time and temperature on your emergency list. During an outage:
- Put the medicines in a cool bag with ice packs from the freezer – but not directly on the ice; frozen insulin is unusable. A towel in between.
- A small min/max thermometer in the bag.
- In winter the problem is more often frost: do not keep medicines in a cold car or on the balcony.
- If unsure: ask the pharmacy or your diabetes team – 1177 is reachable as long as the phone network works.
Powered medical devices
Oxygen concentrators, home ventilators, CPAP machines, electric care beds, suction devices, pumps. There is a clear order here:
- Talk to your prescriber first. Swedish regions have routines for power cuts; Region Blekinge, for example, describes that most oxygen patients also have portable oxygen (cylinders, liquid oxygen or a portable concentrator) that needs no mains power. Ask: what is my plan B, who is responsible, which number do I call?
- Know the runtime: how long does the device run on its built-in battery? Is there an extra battery from the manufacturer? What does the rating plate say about power?
- Only then backup power: a pure sine wave power station can run a CPAP machine overnight if output and capacity are sufficient (switching off the humidifier often cuts consumption considerably – check with your doctor). Follow the manufacturer’s guidance.
- Personal alarm (trygghetslarm): ask the provider or municipality how long it runs on battery in a power cut and whether it transmits via the mobile network – in which case it also depends on that network.
13. Pets and livestock
Pets
MCF: water, food, medicines and warmth for at least one week, oldest food first. A carrier the animal is used to. Pets may not be taken into public shelters – plan another protected space. The organisation Svenska Blå Stjärnan publishes checklists for cats, dogs, birds, reptiles, rodents, rabbits and horses.
Technically relevant:
- Aquarium: without power no aeration, filtration or heating. A battery-powered emergency air pump is cheap and extends the time considerably. Insulate the tank with blankets.
- Terrarium: reptiles need warmth. Hot-water bottles and an insulated box are the non-electric solution; a power station for a heat mat the technical one.
- Feeders and drinking fountains with a mains adapter: do you know how to operate them manually?
Farms with animals
On a farm a power cut is not an inconvenience but an animal welfare issue. Typical critical loads: milking system and milk cooling, mechanical ventilation in barns, drinking water (well pump, heated drinkers), feeding systems, milking robots, lighting.
- The Swedish Board of Agriculture (Jordbruksverket), for example, checks laying-hen houses with mechanical ventilation for emergency ventilation, for more than 2,000 birds an alarm for over-temperature and power failure, and a plan for maintaining animal welfare during a power cut. Other species have their own requirements – check the rules for your operation.
- Many farms use a PTO-driven 400 V generator on the tractor. Connecting it to the farm installation requires an inlet installed by an authorised electrician and notified to the grid operator.
- Work out the diesel supply for tractor and generator for a week – and store it according to the rules.
- The power failure alarm must have its own battery and transmit over the mobile network. Check who receives it at night.
How farm networks and barn cameras fit together is described on the page Wi-Fi and cameras for farms.
14. Five typical households – what matters in each
These are typical situations, not client cases.
A) House with district heating in Sundsvall
Mains water, district heating, induction hob, fibre. Critical: the house circulation pump (a few watts), water after some hours, cooking. Solution: containers and frozen bottles, camping stove and LPG, battery radio. With a wood stove: firewood for a week. A small power station can run the circulation pump if an electrician has made it pluggable – then at least the residual heat from the district heating network circulates as long as it is supplied.
B) Rural house with ground-source heat pump and drilled well
The hardest case: heat and water both depend on power. Critical: heat (below +5 °C after 1–3 days depending on insulation, see table), water after a few litres, sewage if pumped. Solution: the wood stove as the backbone. A generator with an electrician-installed changeover switch for the well pump, circulation pump and fridge/freezer – run in blocks, not continuously. The heat pump only if the generator is demonstrably large enough and the immersion heater is off. Water for at least three days.
C) Flat or terraced house
Little space, no fireplace. Critical: heat, water on upper floors, cooking (barbecue only outdoors at designated spots). Solution: one room, sleeping bags, wool clothing; water in PET bottles; spirit stove; power banks; organise with the neighbours – MCF explicitly suggests sharing more expensive items.
D) Holiday cabin, empty in winter
Here the issue is not your own supply but the building. Critical: frozen pipes, water damage, the chest freezer. Solution: a temperature sensor with mobile connection and battery that alerts below +5 °C; water off and – where possible – drained when nobody is there; someone nearby with a key. How that works without fibre is explained in Camera in a holiday home without broadband. An example of a cabin with no grid connection at all: off-grid cabin case study.
E) Dairy or poultry farm
See section 13. Critical: ventilation, milking, water. Solution: a backup power plan with an electrician and adviser/vet, tractor generator, alarm chain with battery, diesel for a week, an annual full-load test.
15. Printable checklists
Print this section (browser: Print, select pages) and put it in your emergency box. Tick off with a pen.
Checklist A: Preparation (once, then check yearly)
- ☐ Power inventory done: critical devices, ratings, circuits noted
- ☐ One room chosen to keep warm; blankets, sleeping bags, wool clothing available
- ☐ Non-electric heat source available and inspected (chimney sweep) – or a decision where you will go instead
- ☐ Firewood or fuel for a week, stored dry
- ☐ CO alarm (EN 50291, battery) in the room with the stove and in bedrooms; smoke alarms; fire extinguisher, fire blanket
- ☐ Main stopcock found and working; drain plan with photos
- ☐ Water: containers with taps, buckets with lids, PET bottles in the freezer
- ☐ Well: plan B (generator with electrician-fitted changeover switch, hand pump or other source)
- ☐ Fridge at 4 °C, non-electric thermometers in fridge and freezer
- ☐ Camping/spirit stove, full LPG cylinder or fuel, matches, firelighters
- ☐ Battery/wind-up/solar radio; P4 frequency written down
- ☐ Head torch per person, torches, lithium batteries
- ☐ Power banks charged; car charger
- ☐ SE-Alert/emergency alerts switched on in your phone
- ☐ Text alerts from grid operator and water supplier subscribed
- ☐ Phone list on paper; family plan with meeting point and time windows
- ☐ SEK 1,000 cash per adult; card PINs known; two card networks
- ☐ Emergency folder: paper + encrypted USB stick, copy kept elsewhere
- ☐ One month of medicines; cold-storage needs and permitted times noted
- ☐ Medical devices: plan B agreed with the prescriber
- ☐ Animals: food, water, medicines for a week; carrier
- ☐ Municipal support point (trygghetspunkt) located
- ☐ Fuel tank at least half full
Checklist B: Hour 1 after a power cut
- ☐ Note the time (important for the fridge and for compensation)
- ☐ Check: just my house (fuse, RCD) or the whole area?
- ☐ Check the grid operator’s outage map/text, or switch on P4
- ☐ Unplug sensitive electronics (protection when power returns)
- ☐ Leave one lamp switched on so you see when power is back
- ☐ Keep fridge and freezer closed
- ☐ Mains water: fill containers and pans while there is pressure
- ☐ Phone into low-power mode; short text to family
- ☐ Think of elderly neighbours and relatives
Checklist C: Day 1
- ☐ Set up one room: blankets over windows, rug on the floor, doors closed
- ☐ Light the stove – is the CO alarm on? Air the room regularly
- ☐ Generator (if any) outdoors; run in blocks: fill pressure tank and containers, freezer 2–3 hours, charge phones
- ☐ Eat fridge contents first; judge frozen food by the thermometer
- ☐ Cook outdoors or safely set up; save water
- ☐ Radio at fixed times (e.g. news on the hour)
- ☐ Note the indoor temperature – heading towards +5 °C? Plan pipe protection
- ☐ Evening: candles and heaters out before sleeping
Checklist D: Day 3
- ☐ Count supplies: water, fuel, firewood, medicines, cash – enough until day 7?
- ☐ If the house cannot be kept warm: turn off water, drain pipes, move to a support point or friends if needed
- ☐ Freezer: check temperature; in winter move frozen food outdoors in boxes
- ☐ Water: municipal distribution points (P4, krisinformation.se); boil well or lake water
- ☐ Sewage: limit flushing if pumped
- ☐ Medicines: check the cold chain, log use
- ☐ Animals: water (frost!), warmth, food
- ☐ Neighbours: who needs help, what can we share?
- ☐ Test the CO alarm, extinguisher within reach
Checklist E: After the outage
- ☐ Switch devices back on gradually, not all at once
- ☐ Heating/heat pump: acknowledge alarms, reset the immersion heater setting, check temperatures
- ☐ Well: check pump and pressure; have the water tested
- ☐ Check pipes for frost damage (damp, drips, pressure loss)
- ☐ Judge food according to Livsmedelsverket; if in doubt, throw it out
- ☐ Router, NAS, cameras, alarm: all working? Clocks correct?
- ☐ Note the outage duration; from 12 hours you are entitled to outage compensation (see below)
- ☐ Photograph damage, report to your insurer
- ☐ Replace what you used: water, fuel, batteries, cash
- ☐ Lessons learned: what was missing? Update the list
16. The annual test plan
Preparedness that is never tested does not work when it counts. The power station is flat, the generator will not start, the batteries have leaked. Stick this plan inside the lid of your emergency box. The Hesa Fredrik test dates make good reminders.
| When | What | Time |
|---|---|---|
| Monthly | Test button on CO and smoke alarms; check LPG level | 5 min |
| March (Hesa Fredrik test) | Test radio and lamps, check batteries; charge power banks and power station; check/replace stored water | 30 min |
| June (Hesa Fredrik test) | Update the emergency folder (new documents, medication list); count the cash; update the phone list | 30 min |
| August/September | Generator: test run under load (well pump/freezer connected), oil, spark plug, fresh fuel or stabiliser; operate the changeover switch once | 1 h |
| September (Hesa Fredrik test) | Chimney sweep/fire inspection done? Firewood for winter; check heaters and hoses | 1 h |
| October | The house drill: main fuse (or the critical circuits) off for two hours with the whole household. What is missing? Do MCF’s web course “Sju dagar” (about 15 min, in Swedish) together | 2–3 h |
| November | Check the fridge holds 4 °C, top up bottles in the freezer; rotate medicines; rotate pet food | 30 min |
| December (Hesa Fredrik test) | Phone: emergency alerts on? Go through the family plan (especially with children) | 20 min |
About the October house drill: the point is not to sit in the dark for two hours but to find the surprises. Typical findings: the head torch is at the cabin. The LPG cylinder is empty. The stove smokes because the chimney is cold. The garage door will not open – and the car with the radio is inside. For heat pumps and boilers, check the manual first whether switching off the fuse is fine; it usually is, but some systems show a fault afterwards that must be acknowledged.
Generator and fuel
- Petrol ages. Without additives it becomes a problem for the carburettor after some months. Use a stabiliser or alkylate petrol, which keeps much longer, or use up the stock regularly in the lawnmower and car.
- Fuel only in approved containers, not inside the house.
- A generator that has never run under load is a generator you do not know will start your pump.
17. After the outage: restart, compensation, review
Restart
When the power returns, every compressor, pump and heater starts at once – in your house and the whole area. Wait a few minutes before plugging sensitive electronics back in. Check router, NAS and cameras: file systems after a hard shutdown, correct time, recording running. If you ran a generator via a changeover switch: back to mains, then switch off the generator – in the order your electrician specified.
Outage compensation (avbrottsersättning)
Under Sweden’s Electricity Act you are entitled to compensation from your grid operator for a continuous outage of at least 12 hours: 12.5 % of your calculated annual network charge for 12–24 hours, at least 2 % of the price base amount (prisbasbelopp), and 25 % more for each additional started 24-hour period, up to 300 %. An outage only counts as over once power has been on for two hours without interruption. Compensation is normally credited automatically – check your next bills. Damages for broken appliances or spoiled food are a separate claim. Note: the Electricity Act is being replaced by a new electricity market act on 1 January 2027; check the new rules then.
Review
A week after the outage, sit down and go through checklist E. The most valuable information you will ever get is what was missing when it happened for real.
18. Common mistakes
- The generator runs in the garage “with the door open”. CO gets into the house. Always outdoors, away from windows and vents.
- The generator is back-fed into a wall socket with a home-made double-plug lead. Potentially lethal – for you and for line workers. Only via a changeover switch fitted by an electrician.
- The power station has sat in the cupboard for two years. And is flat. Charge it per the test plan.
- The well pump is 400 V. The small 230 V generator is no use. Read the plate before buying.
- The router is on the UPS – the fibre box is not. Both need power.
- The smart home is entirely cloud-controlled. Without internet even the lights will not respond to the app. Local control (for example Home Assistant on your own network) and ordinary wall switches are more robust.
- All phone numbers are only in the phone. Paper.
- Only alkaline batteries in the cold cabin. Almost useless in frost.
- Candles in every room and nobody watching. One room, few light sources, extinguisher within reach.
- The heater stays on overnight. MCF is clear: not while sleeping.
19. What I learned from my own system
At home I run a backup-capable hybrid inverter from the off-grid world with a large battery, monitored with Home Assistant. A few lessons apply to every household, whether you have a home battery, a power station or a generator:
- Every backup solution consumes power itself. My inverter draws around 126 watts at idle – about 3 kWh a day just to be ready. It is fairly power-hungry; branded home battery systems are considerably more frugal (for customer calculations I assume about 15 W including the battery management system). A power station draws less with its inverter on, but not nothing. Include it in your energy budget and switch a power station’s inverter off when nothing is connected. Details are in the measured home battery case study.
- Measure, don’t guess. With a plug-in meter I saw that the washing machine briefly draws over 2 kW during its heating phase, but little otherwise. Exactly these peaks decide whether an inverter or generator can carry a device.
- An alert when the grid fails is gold – my system sends a push notification when the grid drops. But: that notification needs internet. In a widespread outage, a text message from a standalone mobile device with its own battery is more robust.
- The monitoring itself can fail without anyone noticing. My measurement chain once dropped out for more than a day – not a power cut but an equipment fault, and no alert came because the very device that sends alerts was affected. Since then my rule is: every alarm chain needs a “dead man’s switch”, an external point that raises the alarm when the heartbeat stops. For a cabin or a barn, that is the difference between “all quiet” and “nobody knows”.
If you would like to go through this for your home: I do the power inventory with you, measure the critical loads, check router, cameras and alarms for outage resilience and draw up a prioritised plan with a test schedule. Electrical work on the house installation (changeover switch, inlet) is done by an authorised electrician; I prepare it technically and coordinate. Advice on site in the Sundsvall area or remotely, in English, Swedish and German.
Fixed-price packages
- Check plus Power cut – SEK 2,500. About 2.5 hours on site: inventory and measurement of critical loads, runtime calculation, mobile coverage, priority plan, specification for the electrician and a test plan.
- Setup Backup communication & alarm – SEK 3,500 labour plus hardware. 12 V supply or UPS for router and converter, backup internet, alarms via two paths, a heartbeat check and a joint test.
Private customers pay including VAT, businesses and farms excluding VAT. Travel within Medelpad is included. The price of a check is credited if you then order a setup. The RUT deduction applies to work on routers, networks and computers – shown separately on the invoice – but not to alarms, cameras, smart home or remote support. Work on the fixed house wiring is done by an authorised electrician.
Frequently asked questions
Is the agency still called MSB?
No. Since 1 January 2026 it is Myndigheten för civilt försvar (MCF), the Swedish Civil Defence and Resilience Agency, at mcf.se. The 2024 brochure “In case of crisis or war” remains valid, and the home preparedness pages were reviewed in October 2026.
Are 72 hours of supplies enough?
Sweden has recommended one week since 2020 and “at least one week” since 2024. 72 hours is better than nothing but does not cover, for example, a long outage after a winter storm in the countryside.
Will my heat pump work in a power cut?
No. Every heat pump needs electricity. It can run on a sufficiently large generator or a backup-capable home battery if an electrician has installed a safe changeover switch and the immersion heater is switched off in backup mode.
How long does a chest freezer last without power?
MCF says “a couple of days”; manufacturers sometimes state 10–18 hours for upright freezers. It depends on how full it is, the type (chest freezers last longer), location and how often you open it. The figure for your model is in the manual.
What is the difference between VMA, Hesa Fredrik and SE-Alert?
VMA is the warning system. Hesa Fredrik is the outdoor siren, SE-Alert the cell broadcast warning to phones (since July 2026). On any warning: go inside, close windows and ventilation, listen to Sveriges Radio P4.
Can I pay by card when the network is down?
If the shop has power but no data connection, card payment with PIN for food, medicine and fuel is meant to work since 1 July 2026. If the shop has no power, only cash works. MCF and the Riksbank recommend SEK 1,000 per adult.
May I connect my generator to the house wiring myself?
No. Feeding the house installation requires a changeover switch that prevents back-feeding into the grid. It is installed by an authorised electrician who notifies the grid operator. Plugging appliances directly into the generator is fine.
Do I need a CO alarm if I have a wood stove?
Yes, especially during an outage when stoves and heaters run more than usual. A battery-powered alarm to EN 50291 in the room with the stove and in bedrooms. A smoke alarm does not detect carbon monoxide.
How much water should I store?
MCF assumes 3–5 litres per adult per day. For four people for a week that is 84–140 litres. If you cannot store that much, keep at least a basic supply and a plan for where and how to fetch and boil water.
No affiliate links. Recommendations are based purely on hands-on experience.
Want to know what actually stops working in your home during a long power cut – and what to tackle in which order? In the Check plus Power cut (SEK 2,500 incl. VAT, travel within Medelpad included) I do the power inventory on site, measure your critical loads and draw up a preparedness plan with a test schedule. In English. Reply within 24 hours.
Send an enquiry Book a free callExternal sources:
- MCF: Basics of home preparedness (reviewed 19.10.2026, Swedish)
- MCF: brochure “Om krisen eller kriget kommer”
- MCF: Access to water in a crisis
- MCF: Access to heat in a crisis
- MCF: Access to communication in a crisis
- MCF/Riksbank: Payments and cash in a crisis
- MCF: Access to food in a crisis
- MCF/Socialstyrelsen: A month of medicine at home
- MCF: Preparedness for your pets
- Government: MSB renamed MCF
- Energimyndigheten: How fast your house gets cold
- Energimyndigheten: Backup generators and backup heat
- Livsmedelsverket: Power cuts and food in the fridge
- Livsmedelsverket: Crisis preparedness for private wells
- County Administrative Board Stockholm: SE-Alert test
- Umeå Energi Elnät: backup power notification form (example from a grid operator)
- Electricity Act (1997:857), ch. 10 outage compensation
- Medical Products Agency: record CO poisonings 2022
- Svenska Blå Stjärnan: preparedness for animals
- Jordbruksverket: laying hens checklist (emergency ventilation, alarms)