This guide reflects the situation on 22 October 2026. A lot changed in Sweden in 2026 – a new agency name, new warning systems, repealed regulations. The details are in the section What changed in 2026.
Contents
- How this guide is organised
- Power cuts in Sweden: how often, how long, why
- What fails and when – the timeline of a long outage
- Router, cameras, phone: how long does your home network last?
- Backup power: UPS, power station, generator or home battery
- Staying reachable: mobile network, 112, radio, two-way radio
- MCF’s advice as a technical checklist
- Heating: which systems work without power?
- Water and wastewater: mains, private well, pumping station
- Fridge and freezer
- Medical devices and medicines
- Pets and livestock
- Communication within the family
- Supplies with a technical angle
- What do I need? A decision guide per household
- What does preparedness cost? Three levels
- Rules, compensation, tax deductions
- The yearly plan: what to check when
- What I have learned from my own system
- What changed in 2026
- Glossary
- Sources and how to use them
1. How this guide is organised
This site has four in-depth articles on power cuts, each around half an hour of reading with step-by-step calculations, tables and printable checklists. This guide is the entry point: it summarises each article so that you know the key points and can decide whether to read further. It also covers topics that none of the four focuses on: heating and water by type of house, medical devices, animals, family arrangements and supplies where technology matters.
| In-depth article | Mainly answers | For whom |
|---|---|---|
| How long do router, cameras and phone keep running? | What network devices draw, run time step by step, DC instead of an inverter, when the operator’s network fails | Anyone with fibre, cameras, alarms, smart home or a home office |
| Backup power for home and cabin | UPS, power station, generator, EV and home battery with island mode: power, inrush current, switchover time, costs, rules | Anyone who wants more than phone and router running |
| Staying reachable in a power cut | How long masts last, 112 without your own network, texts under overload, P4, PMR446, hunting radio, Starlink, phone battery strategy | Families, farms, small businesses, relatives of elderly people |
| MSB/MCF preparedness advice in practice | Every official recommendation with a technical angle: heating, wells, cooling, radio, cash, documents, five checklists, a yearly test plan | Every household – the best start if you read only one article |
Short of time? Read the timeline and the decision guide for your household here, then print the checklists from the MCF article.
2. Power cuts in Sweden: how often, how long, why
The statistics: mostly short, sometimes very long
The Energy Markets Inspectorate (Energimarknadsinspektionen, Ei) analyses all grid operators’ outages every year. In 2024 the average unplanned outage time was about 63 minutes per customer. The average hides two things that matter for planning:
| Figure (Ei, security of supply report 2024) | Value |
|---|---|
| Average outage time per customer, rural grids (faults in own grid) | 72 minutes |
| the same in urban grids | 16 minutes |
| Customers without power for at least 12 hours in a row | 18,847 |
| Customers without power for more than 24 hours | 6,456 (2023: 3,824) |
| Customers with more than 12 hours in the storm year 2019 | almost 100,000 |
First: in the countryside you are affected far more often and for longer than in town, because overhead lines run through forest. Second: long outages come in waves, with big storms. Storm Gudrun cut power to about 730,000 customers in 2005 and the longest outage lasted 45 days. Afterwards many overhead lines were replaced by underground cable, and since 2011 the Electricity Act has required that an outage must not exceed 24 hours – unless the cause is beyond the grid operator’s control. Other storm years in the statistics are Per (2007) and Dagmar (2011). Two more recent examples from Västernorrland are instructive: after storm Ivar in December 2013, phones still worked in the morning and went dead when the masts’ backup batteries ran flat. During storm Johannes on 27 December 2025, Sundsvall municipality warned of mobile network disruption; two days later, according to TV4, about 4,000 customers of a large grid operator in Västernorrland were still without power.
Five kinds of power cut
| Kind | Typical duration | What it means for you |
|---|---|---|
| Fault in your own house (fuse, RCD) | until you find it | Neighbours have power – check the consumer unit before calling the grid operator |
| Local grid fault (digger, lightning, tree) | minutes to a few hours | Mobile network and fibre node usually keep working; a small battery for the router is enough |
| Storm, snow, ice load | hours to days, longer in rural areas | The serious case this guide is about: heating, water and mobile network become a problem |
| Planned outage | announced, usually hours | The grid operator informs you in advance – sign up for their text alerts |
| Power shortage: manual load shedding | according to Svenska kraftnät probably a couple of hours, rotating | In an acute shortage Svenska kraftnät can order grid operators to disconnect parts of the grid. Disconnections can rotate so that nobody is cut off for too long. For Västernorrland (price area SE2) the county administrative board considers this unlikely. |
Load shedding comes with a term that is often misunderstood: Styrel. It is the planning process in which authorities, municipalities and grid operators decide which lines keep their power longest during a disconnection – based on how important the critical services on those lines are, for example for life and health. Styrel prioritises lines and essential services, not individual households. If someone at home depends on a medical device, do not count on your house being prioritised (more under Medical devices).
The Norrland factor
A winter outage in Västernorrland is a different problem from a summer outage in Skåne. At −20 °C a poorly insulated house cools to +5 °C within a day, lithium batteries must not be charged below freezing and deliver less, alkaline batteries become almost useless, and ice load and snow-broken trees slow repairs. At the same time winter helps: frozen food can be stored outside and snow can be melted in an emergency. Each in-depth article has its own winter section; the figures on batteries in the cold are in the article on router, cameras and phone, and how quickly houses cool down is in the heating section below.
3. What fails and when – the timeline of a long outage
A widespread winter outage is not like flicking a switch; it happens in stages. The times are typical orders of magnitude from the sources of the in-depth articles, not a guarantee – your house, your grid operator and your mast can differ a lot.
| When | What fails | What you do now |
|---|---|---|
| Second 0 | Everything without a battery: fibre media converter, router, Wi-Fi, IP phone, cameras without UPS, heating controls, circulation pump, heat pump, well pump, hob, garage door | Note the time, check the consumer unit, outage map or P4 |
| Minutes | Water pressure from a drilled well (pressure tank empty), pellet burner goes into fault mode | Mains water: fill containers while there is pressure |
| up to 1 hour | Small UPS flat; in larger towns, under the old rules, the first mobile masts; small fibre nodes with no backup requirement | Phone into power saving mode, short text to the family |
| 1–4 hours | More masts, in rural areas after about 4 hours (old PTS requirement); networks slow down because frequency bands may be switched off | Radio for updates, keep fridge and freezer closed |
| 4–7 hours | Fridge contents: according to the Swedish Food Agency, can be judged by look and smell only up to 7 hours (starting at 4 °C) or 4 hours (starting at 8 °C) | Eat from the fridge first, put frozen bottles in |
| 12 hours | Right to outage compensation begins; rooms noticeably cold | Set up one room to keep warm, light the stove |
| 1 day | Old, poorly insulated house at −20 °C close to +5 °C; freezers at their limit depending on the model | Plan frost protection for pipes, move frozen food outside (when freezing) |
| 2–4 days | Even modern houses well cooled; power banks and power stations flat unless recharged | Count supplies, municipal support point, consider moving out |
| 1 week | MCF’s target: how long households should manage on their own | Afterwards: switch on in stages, water test, report damage |
Two conclusions follow. First: your own preparation only helps for as long as the weakest link outside your house holds. A router on a battery is no use once the fibre node in the village has shut down; then you need a second path. Second: the first hours decide. Whoever fills water early, keeps fridge and freezer closed, informs the family and saves phone battery has more room later.
4. Router, cameras, phone: how long does your home network last?
Summary of the in-depth article How long do router, cameras and phone keep running?
Fibre itself needs no power – but there is electronics at both ends that does. In the house it is the media converter (ONT) and router, in the village the operator’s fibre node. Until January 2026 the Swedish Post and Telecom Authority (PTS) prescribed minimum backup times by the number of users affected: large nodes 24 hours, medium ones 8–12 hours, small ones 2–4 hours, and nodes with fewer than 2,000 connections no minimum at all – which is the typical village node. Mobile masts had to last at least 1 hour in towns of more than 8,000 inhabitants and 4 hours everywhere else. This regulation (PTSFS 2022:11) was repealed on 15 January 2026 with the new cybersecurity act; successor rules have been announced but are not in force as of October 2026. The batteries in the networks were built to the old values – plan on that basis.
The key figures
- The basic setup (media converter + router with Wi-Fi) only needs about 10–15 W. Every camera, access point and above all a NAS with hard drives multiplies that.
- A typical small UPS (750 VA) actually delivers only about 35 Wh according to the manufacturer’s runtime curve – one hour, not a storm.
- A 12 V LFP battery with 100 Ah keeps the basic setup running for about three days on DC, but only about 1.7 days through an inverter.
- DC instead of an inverter often saves a quarter to a third of the energy with small loads, because the double conversion 12 V → 230 V → 12 V and the inverter’s idle draw disappear.
- Cold: LFP delivers about 80 % of its capacity at 0 °C and about 50 % at −20 °C (Victron datasheet).
The calculation in one sentence
Run time in hours = usable energy (Wh) ÷ power drawn from the battery (W). Usable energy = nominal voltage × amp-hours × depth of discharge × temperature factor; power from the battery = device consumption ÷ converter efficiency + converter idle draw. Example: household with two cameras, 35 W; LFP 12.8 V × 100 Ah × 0.8 = 1,024 Wh; on DC 35 ÷ 0.91 = 38.5 W → about 27 hours; via an inverter with 6 W idle draw about 20 hours; at −20 °C on DC just over 13 hours. The article works this through for three setups and six energy sources and explains the Peukert effect in lead-acid batteries.
What to do with this
- A battery for media converter and router always pays off – most outages are local and short.
- For long outages, a second path matters (4G/5G router on a different mast, radio link, satellite), not an even bigger battery.
- A NAS belongs on a UPS that shuts it down cleanly – not on backup power that keeps it running for days.
- Test once a year: fuse off, see what actually keeps running.
All the detail – consumption table, PoE from a battery, fusing, phone and alarm, outage alerts to your phone, scenarios and a checklist – is in the in-depth article. What to do with a fresh fibre connection is covered in Fibre installed – what next?
5. Backup power: UPS, power station, generator or home battery
Summary of the in-depth article Backup power for home and cabin
Backup power is usually approached from the device (“I’ll buy a generator”). It works better the other way round, with four questions: What must keep running? For how long? How fast must it switch over? How does the power get to the loads? Answer those and most of the decision is made.
| Option | Power | Duration | Switchover | Electrician needed? | Market price (Oct 2026) |
|---|---|---|---|---|---|
| UPS (line-interactive) | 0.3–3 kW | minutes to hours | a few ms | no | from about SEK 1,300 |
| Power station (LFP, 1 kWh) | up to about 1.8 kW | hours to 1 day | manual or under 10–30 ms | no | about SEK 8,800 |
| EV with V2L | up to about 3.6 kW | 1 day and more | manual | no (V2H: yes) | – |
| Inverter generator | 1–4 kW | as long as fuel lasts | manual | for a changeover switch: yes | about SEK 7,000–16,600 |
| Fixed generator with changeover switch | 5–20 kW and more | as long as fuel lasts | manual or automatic | yes | generator plus electrician by quote |
| Home battery with island mode | 3–12 kW | hours to days | ms to s | yes | 10 kWh about SEK 85,000–110,000, backup equipment extra |
The three key insights
- A home battery is not automatically backup power. Every grid-tied inverter must shut down when the grid fails. Backup needs extra equipment (backup box, transfer switch) that has to be ordered, installed by an electrician and configured. Ask before you sign: power per phase in island mode, switchover time, black start.
- Inrush current decides. Pumps and compressors draw several times their rated current when starting. A generator or inverter that cannot cope will not start the well pump – whatever the continuous rating on the label says.
- Reserve or savings. A battery that is emptied every evening to save money is no help in an outage at midnight. If you want both, you need a fixed reserve.
The article calculates power, energy and run time step by step, compares LFP, NMC and lead-acid in the cold, explains UPS classes under IEC 62040-3, fuel quantities and storage limits, manufacturers’ island-mode solutions, and has a decision tree per scenario. Whether a home battery pays off at all is shown in the case study on a price-controlled home battery.
6. Staying reachable: mobile network, 112, radio, two-way radio
Summary of the in-depth article Staying reachable in a power cut
Communication fails in stages: first Wi-Fi, then the landline (which now runs over IP and dies with the router – the old copper network is being switched off during 2026), and after a few hours often the mobile network. That this is not theory is shown by Ivar in 2013 in Västernorrland and by an outage in Mölndal in spring 2025 in which, according to a parliamentary motion, the mobile network went down completely after an hour and 112 could not be reached.
The essentials
- Emergency calls via other networks: 112 can fall back to another operator’s network – but only if there is coverage, and your location may not be transmitted. If that fails: remove the SIM and dial again, look for better reception, go to the nearest fire station (emergency phone). Be ready to give your location yourself – the coordinates of house and cabin belong on your emergency sheet.
- Older phones: 2G and 3G were switched off by Tele2, Telenor and Tre at the end of 2025, and Telia has switched off 3G; Telia runs 2G until probably the end of 2027. Phones that cannot make emergency calls over 4G are being blocked. This also affects simple phones for seniors, alarm systems and personal alarm buttons.
- Texts beat calls: under overload a text is stored and delivered later; a call is rejected. One message with all the facts instead of five call attempts.
- P4 radio is the emergency broadcast channel and must always be able to transmit. Any radio with batteries, a crank, a solar cell or in the car will do – note the FM frequency in advance.
- Licence-free radio: PMR446 (0.5 W, handheld) for family and neighbours; on farms the 155 MHz hunting and agriculture band (5 W) with much longer range – restricted to farming, forestry and hunting.
- Satellite: Starlink Mini draws about 25–40 W, Standard 75–100 W – on a 12 V LFP battery with 100 Ah about 30 or 11 hours of continuous use, up to two weeks in time windows. Satellite SOS straight from your phone is not confirmed for Sweden as of October 2026.
- Phone battery: with flight mode and fixed time windows a full phone lasts about five days instead of one. A 20,000 mAh power bank realistically delivers just under three full charges, not five.
The article has the PTS table, radio bands with ranges, the battery calculation for a family over a week, templates for a communication plan and a checklist. How to set up phones for elderly relatives is covered in Setting up a phone for elderly parents.
7. MCF’s advice as a technical checklist
Summary of the in-depth article Sweden’s MSB/MCF preparedness advice in practice
Since 1 January 2026 the former MSB has been called Myndigheten för civilt försvar (MCF), in English the Swedish Civil Defence and Resilience Agency, with its pages on mcf.se. The brochure “In case of crisis or war” (Om krisen eller kriget kommer) from November 2024 is still the current household edition and is available in English and many other languages. The goal: everyone who can should manage at least one week with food, water, heat and information. The often quoted 72 hours are better than nothing, but they are not the Swedish recommendation.
The article translates each MCF recommendation into a technical question – which radio, which battery chemistry, how much fuel, what works at the checkout without a network – and starts with the most important step: the power inventory. In 30 minutes you walk through every room and outbuilding, note every appliance, mark it as critical, important or dispensable, copy the power rating from the label and note which fuse supplies it. That gives you your energy budget in watt-hours per day; a worked example without heating and well comes to about 1.8 kWh per day.
Particularly useful there:
- the table of which heating works without power and the firewood calculation,
- the calculation of cooking fuel (about 1 kg of LPG a week just to boil water for four people),
- the overview of what works when you pay without a network – since 1 July 2026, card payments with PIN for food, medicine and fuel should work offline too,
- the guide to an encrypted emergency folder on a USB stick,
- five printable checklists (preparation, hour 1, day 1, day 3, afterwards) and the yearly test plan.
The sections below go deeper into the topics where the question “what exactly happens in my house?” is most often left open.
8. Heating: which systems work without power?
In winter, heat is the question everything hinges on – not just for comfort but for the house: below +5 °C water pipes are at risk. The Swedish Energy Agency (Energimyndigheten) has calculated how quickly twelve typical Swedish houses cool down without power. Some figures:
| House (Swedish Energy Agency) | Indoor temperature after 24 h without power at −10 °C | +5 °C reached at −20 °C after |
|---|---|---|
| Old log house, 1880 | 3.9 °C | just under 1 day |
| Link house 1975, direct electric heating | 10 °C | just over 1 day |
| Terraced house 2005, exhaust-air heat pump | 13.1 °C | 2 days |
| Low-energy house 2007 | about 14–16 °C | 4 days |
The full table is in the MCF article. The lesson: even a modern house gives you less than a week. Without a heat source that works off-grid, MCF’s target cannot be met in winter.
Your heating system: what happens and what you need
| Heating system | In a power cut | Minimum backup load | Realistic strategy |
|---|---|---|---|
| Direct electric radiators | cold immediately | several kW per room | Wood stove, or one room with an LPG/paraffin heater; a generator for the whole house is rarely sensible |
| Air-to-air heat pump | off | depending on model and outdoor temperature a few hundred watts to over 1 kW | Possible on an inverter generator or home battery if connected via a changeover switch – heats one room efficiently |
| Air-to-water and ground-source heat pump | off | compressor plus pumps; the immersion heater draws several kW | Usually not realistic; if so, switch off the immersion heater in emergency mode, check inrush and phases |
| Pellet or oil boiler | burner goes into fault mode | ignition, fan, auger, circulation pump: a few hundred watts, more during ignition | Works well with a generator via changeover switch; check with the manufacturer |
| District heating | residual heat in the network, but the circulation pump in the house stops | circulation pump 4–45 W (example high-efficiency pump) plus controls | A small power station is enough if the pump has been made pluggable (electrician); whether the network keeps supplying depends on the provider |
| Wood boiler with water circuit | risk of overheating without the pump | circulation pump, possibly controls | Only keep firing as the manufacturer allows; backup for the pump is a safety issue here |
| Wood stove, tiled stove, open fireplace | works | none | The backbone of winter preparedness: firewood for a week, chimney swept, CO alarm |
| LPG or paraffin heater | works | none | For one room; ventilate, keep clearances, CO alarm, never while sleeping |
Worked example: what does the circulation pump really need?
Many people underestimate how small this important load is. Assumptions for the example: circulation pump 25 W, controls 10 W, 35 W in total. Over 24 hours: 35 W × 24 h = 840 Wh. A power station with 1 kWh usable capacity and an assumed inverter efficiency of 85 % delivers 1,000 × 0.85 = 850 Wh – about one day. Run the pump only intermittently, when the stove or residual heat warms the water in the circuit, and it lasts much longer. The precondition: the pump is not hard-wired into the consumer unit but has been made pluggable, or given a backup circuit, by an electrician.
Heat pumps and backup power – the essentials
A heat pump does not heat without power. Its high efficiency nevertheless makes it the most interesting candidate for backup power: a room that needs 1.5 kW of heat at −15 °C costs only about 0.75 kW of electricity with an air-to-air heat pump at an assumed COP of 2, but 1.5 kW with a fan heater. An inverter generator with 2–3 kW continuous output can handle that – a 1–2 kWh power station only for a few hours. Whether your heat pump starts cleanly on a generator and how it may be connected is a question for your installer and electrician. The basics of choosing a heat pump in the north are in Heat pumps in northern Sweden.
Frost protection when the house cannot be kept warm
- Find the main water valve and check that it turns; make a draining plan with photos of the valves.
- Trace heating on pipes and well pipe needs power itself – it fails exactly when you need it.
- Never thaw a frozen pipe with a naked flame (MCF) – turn off the water and call a plumber and your insurer.
- Unoccupied cabin: temperature sensor with mobile connection and its own battery that alarms below +5 °C. How remote monitoring and frost protection fit together is covered in Frost protection for your cabin, remotely and in the cabin checklist for winter closing.
9. Water and wastewater: mains, private well, pumping station
MCF is clear: a lack of water is more serious than a lack of food. Allow 3–5 litres per adult per day for drinking, cooking and basic hygiene. For four people over a week that is 84–140 litres – few households store all of it. The strategy is therefore staged: a basic stock for the first days plus a plan for how to get water afterwards. Where your water comes from determines the plan:
| Supply | In a power cut | Your plan |
|---|---|---|
| Municipal mains water | Reservoirs and backup power at key points; pumps and treatment can stop “after a while” according to MCF – houses on high ground and at the end of lines first | On a storm warning or expected long outage, fill containers, pans and the bath (for flushing); have your own containers for emergency water points |
| Drilled well with submersible pump | After a few litres from the pressure tank, nothing | Water for at least three days plus a generator for the pump (changeover switch by an electrician) or another source |
| Dug well | Pump stops, but the water is reachable | Bucket on a rope, hand pump; boil the water |
| Wastewater via pumping station or aerated small treatment plant | Pump stops, the sump fills until it backs up | Limit flushing, ask the manufacturer or municipality about buffer time, pumping station is a candidate for backup power |
Worked example: well pump on a generator
A submersible pump with 1 kW rated power (typically 0.5–1.5 kW) draws several times its rated current when starting. Retailer guideline values for well pumps are around 1,000 W running and 2,800 W starting. The consequence: a generator with 2 kW continuous output may not be able to start this pump, even though 1 kW running load would be no problem. Size for the starting load, and check beforehand whether the pump needs 3×400 V – then no single-phase generator will do. Energy, on the other hand, is not a problem: if the pump runs for 20 minutes a day in total, that is about 330 Wh. Run the generator in blocks: start, fill the pressure tank and containers, stop.
Storing water without a space problem
The MCF tip that solves two problems: fill PET bottles with tap water (not quite full) and freeze them. They are water supply and ice packs in one – first they keep the freezer cold, then the fridge, then you drink them. Store containers dark and cool and check them once or twice a year. After an outage, MCF and the Swedish Food Agency recommend a water test for private wells; boiling kills bacteria but does not remove chemicals. More on wells, hand pumps and pressure tanks in the MCF article.
10. Fridge and freezer
The reliable rules are set out in detail in the MCF article. The short version:
- Fridge: according to the Swedish Food Agency, you can judge food by look, smell and taste if the outage lasted no more than 7 hours (fridge at 4 °C beforehand) or 4 hours (8 °C beforehand). So: set your fridge to 4 °C today and put in a thermometer that needs no power.
- Freezer: MCF says the freezer stays cold enough for “a couple of days” if the door stays shut; a large manufacturer quotes 10–18 hours for its upright freezers. The temperature rise time for your model is in the product data sheet. Full lasts longer than half empty, chest longer than upright, a cold cellar longer than a warm kitchen.
- Winter: when it is freezing, frozen food can be stored outside in closed boxes, protected from sun and animals.
- Backup power: annual consumption from the EU energy label ÷ 365 = daily need, often 0.4–0.8 kWh. Better to power it twice a day for a few hours than continuously. The compressor needs several times its running power to start – the inverter must handle that.
11. Medical devices and medicines
For most households a power cut is inconvenient. For people who depend on an electrical device at home it can be dangerous. This section is deliberately more detailed than in the in-depth articles, because technology and health meet here – and because the most important step is not a technical one.
Step 1: talk to whoever prescribed the device
Before buying backup power, clarify with the clinic, the region’s assistive devices centre or the supplier:
- What is plan B in a power cut? Region Blekinge, for example, describes that most oxygen patients also have portable oxygen (cylinders, liquid oxygen or a portable concentrator) that does not need mains power.
- Who is responsible outside office hours, which number do I call – and does that number work when the mobile network is struggling?
- May the device be run from a power station or generator? Is there an extra battery from the manufacturer?
- How long does the built-in battery last, and how old is it?
Do not count on your house being prioritised in a load-shedding event: Styrel prioritises lines with essential services, not individual households. Ask your grid operator whether they inform customers with life-supporting equipment separately about planned outages – and in any case sign up for their text alerts.
Step 2: know and calculate the run time
| Device | What to clarify | Technical note |
|---|---|---|
| Oxygen concentrator | Is there portable oxygen as a reserve? How long does it last? | Stationary concentrators draw relatively much power – backup only after consultation |
| CPAP / home ventilation | Battery operation possible? Can the humidifier be switched off in emergency mode? | The humidifier often increases consumption considerably; pure sine wave needed |
| Electric care bed, patient hoist | Manual emergency lowering? Battery? | Mostly short, high loads – keep the device battery charged |
| Suction device, pumps | Battery, spare device, run time | Check chargers for 12 V or USB-C |
| Personal alarm (trygghetslarm) | How long on battery? Over which network? | Usually runs over the mobile network – and then depends on the mast |
Worked example CPAP (assumptions, not manufacturer data): device without humidifier 40 W, eight hours of sleep: 40 W × 8 h = 320 Wh per night. Power station with 1,024 Wh nominal capacity, assume 80 % usable through the built-in inverter: about 820 Wh, so just over two nights. With a humidifier the need can multiply. If the device runs on 12 V or 24 V DC and the manufacturer offers an approved cable, the inverter loss disappears – then it is more like three nights. The real values are on the rating label or in the manual; measure one night with a plug-in energy meter.
Step 3: medicines
- A month’s supply: the National Board of Health and Welfare (Socialstyrelsen) recommends a month’s supply of prescription medicines you take regularly – including consumables such as blood glucose test supplies. There are exceptions, for example for multi-dose bags and certain controlled drugs.
- Refrigerated medicines (insulin, biologics, some eye drops): read the leaflet now and write the permitted time and temperature without refrigeration on your emergency list. During an outage: cool bag with ice packs, but never directly on the ice – frozen insulin is unusable. A min/max thermometer in the bag.
- Medication list with active substance and dose, on paper and in the encrypted emergency folder (see documents).
Step 4: the human plan
Anyone who lives alone and depends on a device or a personal alarm needs, besides technology, a person who checks in during an outage. Agree it concretely: who, when, and what happens if nobody gets through. The municipality can tell you where it opens support points (trygghetspunkter) during major disruptions.
12. Pets and livestock
Pets
MCF recommends water, food, medicine and warmth for at least one week and a carrier the animal is used to. Technically relevant are mainly animals whose environment needs power:
- Aquarium: no power means no aeration, filtration or heating. A battery-powered emergency air pump is cheap and extends the time considerably; insulate the tank with blankets.
- Terrarium: reptiles need warmth – hot-water bottles and an insulated box without power, a heat mat on a power station with. Calculate as above: power × hours.
- Feeders and water fountains with a power adapter: do you know how they work manually?
- The organisation Svenska Blå Stjärnan has checklists for many kinds of animals.
Farms with animals: animal welfare, not comfort
On a farm a long outage is an animal welfare problem. Typical critical loads are mechanical barn ventilation, milking system and milk cooling, drinking water (well pump, heated drinkers), feeding systems and milking robots.
- Rules: under the EU farm animal welfare directive 98/58/EC, buildings with mechanical ventilation need a back-up system and an alarm that signals a failure and is tested regularly. The Swedish Board of Agriculture (Jordbruksverket), for example, checks for laying hens in mechanically ventilated houses that there is emergency ventilation, an alarm for over-temperature and power failure from 2,000 birds, and a plan for animal welfare in a power cut. Insurers also have requirements for operational alarms and standby generators.
- Calculate the water: a dairy cow drinks about 70–80 litres a day according to SLU data quoted in a manufacturer brochure. 50 cows therefore need 3,500–4,000 litres a day – no bucket can do that, it is a question of pumps and backup power.
- Backup power: common is a tractor-driven, three-phase PTO generator (market prices for 30 kW about SEK 44,000–64,000) or a stationary diesel generator, connected via a changeover switch installed by an electrician. Be honest about the starting loads of vacuum pump, milk cooling, ventilation and feeding motors, store diesel for a week according to the rules, and test under load once a year.
- Alarms: the power-failure alarm needs its own backup power and must not rely only on the mast that is going down: local siren or strobe, a second mobile operator, an arrangement with neighbours. And an external heartbeat check that raises the alarm when the alarm chain itself dies.
More in the backup power article (farm scenario), the MCF article and on the page Wi-Fi and cameras for farms.
13. Communication within the family
Technology does not replace an agreement. The best power bank is useless if nobody knows when to try to reach whom. MCF explicitly advises keeping numbers on paper and agreeing a meeting point. The template in the article on staying reachable can be filled in in half an hour at the kitchen table. The key points:
| Question | Why it matters technically |
|---|---|
| First channel: text message, one message with all the facts | Texts are stored under overload, calls are rejected |
| Second channel: a second SIM from another operator, or PMR446 on an agreed channel | Different masts, or no infrastructure at all |
| Fixed time windows (e.g. 8, 12, 18, 21 for ten minutes) | Saves phone battery – flight mode in between stops the power-hungry network search |
| Contact person in another region | Long-distance calls often get through when everything local is overloaded; everyone checks in there |
| Meeting point and backup meeting point | For when nothing works any more |
| Who picks up the children, who looks in on older relatives? | Schools and nurseries are hard to reach too |
| Phone list and coordinates on paper | The contacts in a flat phone are useless; with emergency calls via another network your location may be missing |
Children, teenagers, older relatives
- Children should know: where is the meeting point, whom do I call, where is the fire station? A note in the school bag is enough. Do the house test (fuse off for two hours) together – children usually treat it as an adventure.
- Teenagers are the biggest data users. The rule “no videos, no voice messages in the first hours” saves both battery and mast.
- Older relatives: check that their phone can make emergency calls over 4G, that emergency alerts (SE-Alert) are switched on and that there is a battery radio in the house. Setting up a phone for elderly parents helps. And: crises are peak season for scams (“your outage compensation – click here”); grid operators pay compensation automatically. More in Phone and SMS scams in Sweden.
14. Supplies with a technical angle
Food lists are available from MCF. This is about the supplies where technology and physics decide whether they work when needed – and how often you have to check them.
| Supply | How much (guideline) | Technical catch | Check |
|---|---|---|---|
| Batteries for radio and torches | A full spare set per device | Alkaline loses a lot in the cold; lithium primary cells (AA/AAA, non-rechargeable) cope with cold and store for years; do not store them in the devices | yearly |
| Power banks | For a family using the saving strategy, two of 20,000 mAh | Realistically 60–70 % reaches the phone; do not charge below 0 °C; they age even unused | recharge every 3–6 months |
| Power station | according to your energy budget | Inverter idle draw; self-discharge | charge quarterly, test under load yearly |
| LPG for the stove | Four people: about 1 kg a week just to boil water, 2–3 kg with cooking | Store cylinders upright; regulations MSBFS 2020:1 | level monthly |
| Firewood | One room, 10 h a day: about 35–40 kg a week (calculation in the MCF article) | Only dry wood gives the energy; store close to the house | autumn |
| Generator fuel | Small inverter generator: about 0.5–1 l per hour at full load | Privately usually max. 25 l of petrol in a garage or shed, about 100 l in total without a permit (municipal guidance); petrol ages, alkylate petrol lasts longer; winter-grade diesel | renew or use up yearly |
| Water | 3–5 l per person per day | PET bottles in the freezer = ice packs | 1–2 times a year |
| Cash | SEK 1,000 per adult, various notes | Shops may refuse cash; without power in the shop only cash works | count yearly |
| Medicines | one month | Cold chain, expiry dates | rotate |
| Spare fuses, outdoor extension leads, 12 V charging cables | one set | Cable size to suit the load, unroll fully | at the test run |
| CO and smoke alarms | Room with the stove, bedrooms | CO alarm to EN 50291 with battery; the sensor ages | test button monthly |
The calculations are in the in-depth articles: power banks and phone charges in the article on staying reachable, fuel and storage in the backup power article, LPG and firewood in the MCF article.
15. What do I need? A decision guide per household
The profiles below are typical situations, not customer cases. Find the one closest to your household. Level 1 makes sense for every household and costs little, level 2 covers the most important loads, level 3 is for households where a long outage means costly damage or danger.
Three questions first
- Does your heating or water depend on electricity? Yes → plan heating and water first (sections 8 and 9), then everything else.
- Does anyone in the household depend on an electrical device, or do you keep animals that need ventilation or pumps? Yes → those loads are level 3, regardless of anything else.
- Do you live in the countryside, on an overhead line through forest? Yes → expect days, not hours, and plan a recharging source (generator, car, solar).
| Household | Biggest risk | Level 1 | Level 2 | Level 3 |
|---|---|---|---|---|
| Flat in town | Cold, water on upper floors, cooking | Radio, torches, power banks, water in PET bottles, spirit stove, sleeping bags, cash | Mini UPS for the router | rarely needed; organise the neighbours |
| Terraced house with district heating | Circulation pump stops, water | as flat, plus CO alarm if there is a fireplace | Power station for circulation pump (made pluggable by an electrician), router, lights | Wood stove |
| Detached house in town with heat pump | Heat | Level 1 plus firewood and CO alarm if there is a stove | UPS for the router, power station for cooling and lights | Backup distribution board with changeover switch and generator from about 5 kW, or a home battery with island mode |
| Country house with ground-source heat pump and drilled well | Heat and water at the same time | Level 1, water for three days, wood stove and firewood for a week | Inverter generator for cooling, router, charging; 12 V solution for the router with backup 4G | Changeover switch by an electrician for well pump, circulation pump, fridge and freezer – generator sized for starting load |
| Cabin, empty in winter | Frost, water damage, freezer | Turn off and drain the water, key holder nearby | Temperature sensor with mobile connection and battery, router and camera on a 12 V battery, power-cut alert | Generator with auto-start and fixed changeover switch, remote monitoring with external heartbeat |
| Off-grid cabin | Dark weeks, snow on panels, faults | Spare fuses, load priorities defined | Generator to recharge the battery | Remote monitoring of battery and temperature; see the off-grid cabin case study |
| Small business | Data, till, cooling, being reachable | Phone list, call forwarding prepared, printouts of the day’s jobs | UPS with automatic shutdown for server/NAS, network and till; backup internet | Generator with changeover switch for cooling and operations |
| Farm with animals | Ventilation, milking, drinking water | Plan with vet/adviser, arrangement with neighbours | Alarm with its own battery via two paths | PTO or diesel generator, three-phase via changeover switch, diesel for a week, yearly full-load test |
Backup power decision tree
- Must there be no interruption at all (computer, heating controls, medical device)? → UPS for exactly those devices, regardless of anything else.
- Is one day enough? → power station, EV with V2L or home battery with island mode. More than a day? → add a recharging source: generator or solar.
- More than 3–4 kW, three phases or large motors? → fixed generator with changeover switch or three-phase home battery with backup, both with an electrician. Otherwise portable solutions are enough.
- Only communication to protect? → 12 V DC solution instead of large 230 V equipment.
16. What does preparedness cost? Three levels
Market prices as of October 2026 from Swedish shops and price comparison sites, including VAT; they vary and are not recommendations of particular models. The sources are in the in-depth articles.
| Level | Typical content | Order of magnitude |
|---|---|---|
| Level 1: basic kit | Battery radio, head torches, lithium batteries, two power banks, CO alarm, water containers, camping stove with LPG, thermometers for fridge and freezer | usually a few thousand SEK, much of it is already in the house |
| Level 2: important loads | UPS 750 VA (from about SEK 1,300) or 12 V LFP 100 Ah (about SEK 2,000–3,300 budget, brand-name about SEK 7,000–7,500) with converters; power station 1 kWh (about SEK 8,800); inverter generator (about SEK 7,000–16,600) | about SEK 2,000–25,000 |
| Level 3: house or farm | Generator 6–8 kW or PTO generator (30 kW about SEK 44,000–64,000) plus changeover switch by an electrician (by quote); or home battery 10 kWh about SEK 85,000–110,000 plus backup equipment | from about SEK 20,000 to over SEK 100,000 |
For comparison: outage compensation for 36 hours, with annual grid charges of SEK 8,000, comes to about SEK 3,000. Backup power rarely pays for itself in money, but in damage avoided – a burst water pipe or dead animals cost many times more.
17. Rules, compensation, tax deductions
- Electrical work on the fixed installation – changeover switch, generator inlet, backup distribution board, backup box, hard-wired inverter – may only be carried out by an electrical installation company with an authorised electrician (behörig elinstallatör). Plug-in devices and extra-low-voltage wiring between battery and devices you may build yourself – with fuses and suitable cables.
- Prevent back-feeding: a generator is only connected to an installation that is disconnected from the grid; the electrician notifies the grid operator. Do not work on the electrics during an outage – power can return without warning (Swedish National Electrical Safety Board, Elsäkerhetsverket). Never touch fallen lines.
- Carbon monoxide and fuel: generators outdoors only, CO alarm indoors, observe the fire and rescue service’s quantity limits.
- Outage compensation (avbrottsersättning): from 12 hours of continuous outage, 12.5 % of the estimated annual grid charges, at least 2 % of the price base amount (prisbasbelopp), plus 25 % for each further 24-hour period begun, up to 300 %. An outage only counts as over after two hours of uninterrupted supply. Payment is automatic. Damages for appliances or food are a separate claim.
- From 2027: the Electricity Act (ellagen) is replaced on 1 January 2027 by the new Electricity Market Act (elmarknadslag, 2026:1281). Check the compensation rules again then.
- Deductions: the green technology deduction (grön teknik) for a battery (50 % of labour and materials, up to SEK 50,000 per person per year) only applies if it is connected to grid-tied self-generation – a pure backup battery without solar panels gets no deduction. The RUT deduction for IT services in the home does not cover alarm systems, cameras or smart home; remote support does not qualify for RUT either. Whether an electrician’s work qualifies for ROT is something to clarify with the electrician.
- Animals: back-up system and alarm for mechanical ventilation (directive 98/58/EC), requirements of the Board of Agriculture and your insurer.
18. The yearly plan: what to check when
Preparation that is never tested does not work when it matters: the power station is flat, the generator will not start, the batteries have leaked. The test dates of the outdoor siren Hesa Fredrik (first Monday that is not a public holiday in March, June, September and December, 15:00) are useful reminders. Combined from all four in-depth articles:
| When | What |
|---|---|
| Monthly | Test CO and smoke alarms, check LPG level |
| March | Radio, torches, batteries; charge power banks, power station, two-way radios; check water containers |
| June | Update emergency folder and phone list, count cash, check coverage of all networks at the house |
| August/September | Generator under load (well pump, freezer), oil, fresh fuel, operate the changeover switch once; chimney and firewood |
| October | House test: main fuse off for two hours with everyone at home; measure UPS and battery run time; did the outage alert arrive? |
| November | Fridge at 4 °C, top up bottles in the freezer, rotate medicines and pet food |
| December | Emergency alerts on the phone active? Go through the family plan |
The detailed plan with time estimates is in the MCF article, the network test procedure in the network article.
19. What I have learned from my own system
At home in Stöde I run a three-phase hybrid inverter from the off-grid world with a large battery, controlled through Home Assistant. I do not have solar panels yet; the battery charges from the grid when prices are low. The fibre converter and router are deliberately connected to the inverter’s output and keep running from the battery when the grid fails. The lessons spread across the in-depth articles, in one place:
- Backup power is an operating mode, not a device feature. By design the battery does not drop below about half; below that there is a hard floor of 30 % that the controller defends regardless of the electricity price.
- Pre-charge before storms and cold. On a yellow or higher SMHI warning for wind, snow or rain, or a forecast of −20 °C or colder, the controller pre-charges even at higher prices.
- Every backup solution uses power itself. My inverter draws about 126 W at idle (my own measurement), which makes it fairly power-hungry; branded home battery systems are considerably more frugal, and for customer calculations I assume about 15 W including the battery management system (BMS). For a whole house 126 W is acceptable; for a router alone it would be absurd – a small 12 V solution is far more efficient for that. Measurements are in the home battery case study.
- Losing one phase means losing everything. If one of the three phases fails – the cause can be the grid or your own main fuse – my inverter goes into fault mode. The controller therefore monitors each phase separately.
- Range, not state of charge. The alert to my phone gives the estimated range at the current load. “Enough for another 14 hours” helps you decide; “70 %” does not.
- The alert path fails too. Because the internet often goes with the power, messages are stored and delivered once the connection is back.
- The monitoring itself can fail. Once, my measurement chain was down for more than a day – a device fault, not a power cut – and no alert came, because it was precisely the reporting device that was affected. Since then my rule is: every alarm chain needs an external heartbeat that raises the alarm when messages stop arriving.
- Cold and the main fuse set limits. The battery is kept frost-free; with a 20 A main fuse it is not full again within an hour after a long outage.
At my own holiday cabin, fibre, a 4G/5G router and a radio link are all in use. How the options compare for cabins is covered in Cabin internet in Sweden.
20. What changed in 2026
Many guides online are out of date on these points. As of October 2026:
| What | New | What it means for you |
|---|---|---|
| Agency | Since 1 January 2026 MSB (Myndigheten för samhällsskydd och beredskap, the Swedish Civil Contingencies Agency) has been called Myndigheten för civilt försvar (MCF, the Swedish Civil Defence and Resilience Agency), website mcf.se | Old msb.se links are redirected; the advice still applies |
| Backup power in telecom networks | PTSFS 2022:11 repealed since 15 January 2026, new rules planned | No hour requirement in force; plan with the old orders of magnitude |
| Warnings to phones | SE-Alert (cell broadcast) since 2026, first test on 7 September 2026 | Keep emergency alerts switched on; works only as long as the mast is running |
| Payments | Since 1 July 2026 card payments with PIN for essentials should work offline | Know your PIN; without power in the shop only cash helps |
| Landline | Copper network switched off during 2026 | The old phone that worked in a power cut is gone |
| Mobile networks | 2G/3G largely switched off (Telia 2G probably until end of 2027); phones without 4G emergency calling are blocked | Check older phones, alarm systems and personal alarm buttons |
| Electricity Act | From 1 January 2027 Electricity Market Act (2026:1281) | Check compensation rules again in 2027 |
21. Glossary
| Term | Meaning |
|---|---|
| Watt (W) / watt-hour (Wh) | Power is what a device draws at a given moment; energy (Wh) is power times time. Batteries store energy; inverters and generators deliver power. |
| Amp-hour (Ah) | A battery’s charge; multiplied by voltage it gives energy: Wh = Ah × V. |
| VA | Apparent power, often quoted for UPS units; the usable real power in watts is lower. |
| Inrush / starting current | The short, high current when motors (pumps, compressors) start, often several times the rated current. |
| UPS | Uninterruptible power supply; takes over within milliseconds, but usually only briefly. |
| Online UPS | UPS in which the devices always run through the inverter: 0 ms switchover, clean sine wave. |
| Power station | Portable battery with sockets, USB and usually a 12 V output. |
| LFP | Lithium iron phosphate: robust battery chemistry with long cycle life; must not be charged below 0 °C. |
| Peukert effect | Lead-acid batteries deliver less energy the faster they are discharged. |
| Inverter | Turns direct current (battery) into alternating current (230 V); has an idle draw. |
| Island mode / backup | The inverter supplies the house itself once it is disconnected from the grid; usually needs extra equipment. |
| Changeover switch (grid–0–generator) | Switch installed by an electrician that keeps grid and generator mechanically separate. |
| V2L / V2H | Vehicle-to-load: the EV supplies 230 V to devices. Vehicle-to-home: the EV supplies the house (bidirectional charger, electrician). |
| Media converter (ONT) | The box where the fibre ends in the house; needs power. |
| PoE | Power over Ethernet: power for cameras and access points over the network cable. |
| Hydrofor | The pressure tank of a well water system; buffers only a few litres. |
| VMA / Hesa Fredrik | Viktigt meddelande till allmänheten, Sweden’s public warning system; Hesa Fredrik is the outdoor siren. |
| SE-Alert | Warnings by cell broadcast to all phones in an area, without an app. |
| P4 | Sveriges Radio P4, the emergency broadcast channel in a crisis. |
| 113 13 | National information number for serious accidents and crises; 112 only for emergencies. |
| Trygghetspunkt | Support point opened by the municipality with information, warmth, water and charging. |
| PMR446 | Licence-free handheld radio with 0.5 W. |
| Avbrottsersättning | Statutory compensation from the grid operator after a 12-hour outage. |
| Styrel | Planning of which lines keep power longest during load shedding. |
| MCF | Myndigheten för civilt försvar (Swedish Civil Defence and Resilience Agency), MSB until the end of 2025. |
| Authorised electrician | Electrician authorised under the rules of Elsäkerhetsverket; only they may work on the fixed installation. |
| CO alarm | Carbon monoxide alarm, standard EN 50291; detects CO, not smoke. |
22. Sources and how to use them
All figures in this guide come from the sources linked below or from the in-depth articles, where each statement is referenced individually. Where I calculate with assumptions, it says “worked example”. For your device, the rating label always applies. Three sources are worth bookmarking: MCF’s home preparedness pages, krisinformation.se (also as an app, with information in English) and your grid operator’s outage map. Weather warnings come from SMHI. The full list is at the bottom of the page.
If you would like to go through this for your home, cabin or farm: I take the inventory, measure the critical loads, check router, cameras and alarms for resilience and write up the specification for your electrician. Electrical work on the fixed installation is done by an authorised electrician; I prepare it technically and coordinate. Advice on site in the Sundsvall area or remotely, in English, Swedish and German.
Fixed-price packages
- Check plus Power cut – SEK 2,500. About 2.5 hours on site: inventory and measurement of critical loads, runtime calculation, mobile coverage, priority plan, specification for the electrician and a test plan.
- Check Power cut network – SEK 1,500. About 1.5 hours, network, phone and cameras only: what depends on what, how long it lasts, what is missing. SEK 750 after RUT for the part covering router and network; cameras do not qualify for RUT.
- Setup Backup communication & alarm – SEK 3,500 labour plus hardware. 12 V supply or UPS for router and converter, backup internet, alarms via two paths, a heartbeat check and a joint test.
- Setup Backup power monitoring – SEK 3,500 plus hardware. For an existing home battery: outage detection per phase, phone notification with estimated range, pre-charge rules for storms and cold.
Private customers pay including VAT, businesses and farms excluding VAT. Travel within Medelpad is included. The price of a check is credited if you then order a setup. The RUT deduction applies to work on routers, networks and computers – shown separately on the invoice – but not to alarms, cameras, smart home or remote support. Work on the fixed house wiring is done by an authorised electrician.
Frequently asked questions
How long does a power cut in Sweden usually last?
Usually not long: in 2024 the average unplanned outage time was about 63 minutes per customer per year, much less in towns than in rural areas. Even so, about 6,450 customers were without power for more than 24 hours in 2024, and after storms such as Gudrun in 2005 it was weeks.
How long should I be able to manage on my own?
At least one week, according to Sweden’s civil defence agency MCF (formerly MSB). 72 hours are better than nothing but not enough for a long outage after a winter storm in the countryside.
What stops working first in a power cut?
Immediately, everything without a battery: router and media converter, IP phone, heating controls, circulation pump, heat pump and well pump. After a few minutes the water pressure from a drilled well, after one to four hours often the first mobile masts.
Which heating works without electricity?
Only wood stoves, tiled stoves, open fireplaces and LPG or paraffin heaters. Heat pumps, pellet and oil boilers and even district heating need power, at least for pumps and controls. With district heating a small power station for the circulation pump is often enough.
Does the mobile network work during a power cut?
For a while. Under the rules in force until January 2026, masts had to last at least 1 hour in larger towns and 4 hours in rural areas. The regulation has been repealed, but the batteries were built to those values. Texts get through more often than calls under overload.
Does my home battery provide backup power automatically?
Usually not. Grid-tied inverters must shut down when the grid fails. Backup needs extra equipment such as a backup box or transfer switch, installed by an authorised electrician. Ask about power per phase and switchover time.
Can I connect a generator to my house wiring?
Only via a changeover switch installed by an authorised electrician and notified to the grid operator. Feeding in through a socket is prohibited and potentially lethal. Running appliances directly from the generator is fine – and the generator always stands outdoors.
What should I do about medical devices in a power cut?
First clarify with whoever prescribed the device, or the assistive devices centre, what plan B is and who is responsible. Then find out the battery run time and use a power station or generator only if the manufacturer approves. Do not count on individual households being prioritised.
Do I get compensation for a long power cut?
Yes. From 12 hours of continuous outage the grid operator automatically pays outage compensation: 12.5 % of annual grid charges, at least 2 % of the price base amount, plus 25 % for each further 24-hour period begun, up to 300 %. A new law applies from 2027.
Where do I start if I want to keep costs down?
With the power inventory (30 minutes, free), a battery radio, two power banks, a CO alarm, water containers, a phone list on paper and SEK 1,000 in cash per adult. Then protect the loads that are genuinely critical in your home.
No affiliate links. Recommendations are based purely on hands-on experience.
Not sure where to start with your home, cabin or farm? In the Check plus Power cut (SEK 2,500) I go through what fails in a long power cut, measure the critical loads and draw up a plan with priorities – from the battery for your router to the specification for your electrician. On site in Medelpad, in English. Reply within 24 hours.
Send an enquiry Book a free callExternal sources:
- MCF: Basics of home preparedness (Swedish)
- MCF: brochure “In case of crisis or war”
- MCF: Access to water in a crisis
- MCF: Access to heat in a crisis
- MCF: Access to communication in a crisis
- MCF/Riksbank: Payments and cash in a crisis
- MCF/Socialstyrelsen: A month of medicine at home
- MCF: Preparedness for your pets
- MCF: Access to food in a crisis
- Government: MSB renamed MCF
- Krisinformation: Power cuts (English)
- Ei: Security of supply in Swedish grids 2024 (Ei R2025:17)
- Electricity Act (1997:857): functional requirement and outage compensation
- Act (2026:1282) introducing the Electricity Market Act
- County Administrative Board Västernorrland: energy supply, Styrel
- PTS: PTSFS 2022:11 (until 14 Jan 2026)
- PTS: repeal of security regulations
- PTS: Controlled shutdown of 2G and 3G networks
- Riksdag: motion 2025/26:2661 (Mölndal outage)
- Sundsvall municipality: storm Johannes
- SVT: mobile network after storm Ivar
- County Administrative Board Stockholm: SE-Alert test
- Swedish Energy Agency: How quickly your house gets cold
- Swedish Energy Agency: Backup generators and backup heating
- Swedish Food Agency: Power cuts and food in the fridge
- Swedish Food Agency: Crisis preparedness for private wells
- Elsäkerhetsverket: During a power cut
- Umeå Energi Elnät: backup power notification form (example from a grid operator)
- CDC: Avoiding carbon monoxide poisoning
- Swedish Tax Agency: Green technology deduction
- Region Blekinge: Home oxygen during power cuts
- Directive 98/58/EC, annex (mechanical ventilation, alarms)
- Swedish Board of Agriculture: laying hens checklist
- DeLaval (SLU data): water intake of dairy cows
- Svenska Blå Stjärnan: Crisis preparedness for animals
- Victron: LFP datasheet (capacity in the cold)
- APC: runtime graph Back-UPS 750 VA