This article is part of the series on power cuts in Sweden. The overview of all topics – including heating, water, medical devices, animals and a decision guide per household – is in the complete guide to power cuts in Sweden.
Contents
- The chain: why the internet disappears in a power cut
- What actually fails first – at the operator
- How long do power cuts last in Sweden?
- Inventory: what your devices draw
- Calculating runtime – step by step
- Energy sources compared: UPS, power bank, LFP battery
- DC instead of an inverter: 12 V routers, PoE, USB-C
- Priorities: what should run, and for how long?
- Phone, 112 and alarms
- How do you even know the power is off?
- Norrland winter: cold, storms, ice
- Scenarios: house, flat, cabin, off-grid, business, farm
- How to test: the planned power cut
- What does it cost?
- Common mistakes
- Maintenance: what to check and when
- Printable checklist
The chain: why the internet disappears in a power cut
The fibre itself needs no power – it carries light. But there is active electronics at both ends of the fibre, and that needs electricity. For a message to get from your house out into the world, every link in this chain has to work:
- Your media converter (in Swedish usually mediakonverter or fiberbox, technically an ONT): the small box on the wall where the fibre ends. It turns light into a network signal and runs on its own plug-in power adapter.
- Your router: shares the connection around the house and handles Wi-Fi and the firewall. Some operators combine it with the media converter in one box.
- Switches and access points: in larger homes and businesses, often a PoE switch that powers cameras and Wi-Fi access points over the network cable.
- The end devices: cameras, NAS, phone base station, alarm system, smart-home hub, laptop.
- The operator's fibre node: a cabinet in the village, in the basement of a block of flats or in a small equipment hut, where the fibres from many households come together.
- The wider network: links to the nearest town and into the operator's core network.
Links 1 to 4 are in your hands; links 5 and 6 are not. If the power fails only at your place – main fuse tripped, a fault on your road – the village node still has power, and a small battery for the media converter and router is enough to stay fully online. If the whole area loses power, everything depends on whether the node has its own backup supply and how long it lasts. That is the key idea of this guide: your backup power can only help for as long as the weakest link outside your house holds out. For the time after that you need a second path – usually the mobile network.
The mobile network has its own chain: your phone or 4G/5G router, the nearby mast and the mast's own link into the network – which often runs over fibre or a radio link itself. A mast with a battery does not help if its backhaul goes through a node without backup power. How long the masts last is covered in the next section.
What actually fails first – at the operator
The rules until January 2026: minimum times by size
The Swedish Post and Telecom Authority (PTS) long set concrete requirements for how long networks must ride through a power cut. The regulation PTSFS 2022:11 applied from 1 August 2022 to 14 January 2026. It grouped network assets by the number of users who would be affected if they failed:
| Class | Users affected | Minimum time on backup power |
|---|---|---|
| A and B | 30,000 or more | 24 hours |
| C | 8,000 or more | 8 hours in towns of over 8,000 people, otherwise 12 hours |
| D | 2,000 or more | 2 hours in towns of over 8,000 people, otherwise 4 hours |
| E | under 2,000 | no minimum |
| Mobile networks (in addition) | coverage from base stations | 1 hour in towns of over 8,000 people, 4 hours everywhere else |
If you live in the countryside, two rows matter most. First: the fibre node of a village or a small local network usually has far fewer than 2,000 connections. There was no backup requirement for it. Whether it has a battery, and how big, is up to the network owner. PTS itself writes in its guidance on secure communication services that wired connections often have no backup power unless the customer has specifically asked for it. Second: mobile masts outside larger towns were built for at least 4 hours. The regulation explicitly allowed operators to switch off frequency bands during a power cut to save energy. The network is still there, but slower and more easily congested.
What applies since 15 January 2026
With Sweden's new Cybersecurity Act, which implements the EU NIS2 directive, PTS repealed PTSFS 2022:11 in full on 15 January 2026. The authority is drafting new rules on security measures and expects at least equivalent requirements to apply; the aim is to have them in place by the end of 2026. As of October 2026, there is therefore no hour figure in force. For your planning it makes little difference: the batteries and generators in the networks today were sized to the old values. Plan with those orders of magnitude – not with more.
The realistic sequence in a widespread outage
- Second 0: everything in your home without a battery goes dark – media converter, router, Wi-Fi, cameras, IP landline, smart home.
- Minutes to a few hours: small fibre nodes with no battery or a small one fail. From then on, even the best home battery will not keep the fibre alive.
- First hour: lots of people switch to mobile at once. Masts carry more load than usual, and because operators may switch off frequency bands in emergency mode, things slow down.
- After 1 to 4 hours and later: masts without generators fall silent one after another – first in towns, then in the countryside. Where masts have generators, or generators are brought in, service continues.
- From about 24 hours: even large nodes and core networks reach the limits of their backup unless someone refuels them.
PTS itself regards long power cuts as the biggest risk to electronic communications. In everyday life, telecom outages caused by power cuts are rare: only four such incidents were reported to PTS for 2024. Both statements fit together. Networks handle short, local outages well; widespread, long outages after storms are where it gets tight. A pilot project by PTS and Telia shows it can be done differently: a base station with hydrogen-based backup power designed to run for at least ten days and up to 110 days. For now, that is the exception.
What does this mean in practice? A battery of your own for the media converter and router is always worthwhile, because most outages are local and short. For long outages you need a second path (mobile via another mast or operator, a radio link, satellite) and, for when everything is down, a radio for Sveriges Radio P4 and knowing where the nearest fire station with an emergency phone is.
How long do power cuts last in Sweden?
The Energy Markets Inspectorate (Ei) analyses all network operators' outages every year. For 2024, the average outage time was about 63 minutes per customer per year. Almost 55% of customers had no long unplanned outage at all. But the average hides large differences:
| Indicator (Ei, 2024) | Value |
|---|---|
| Average outage time per customer, rural networks (faults in own network) | 72 minutes |
| the same in urban networks | 16 minutes |
| Customers with at least 12 hours without power in one go | 18,847 |
| Customers with more than 24 hours without power | 6,456 (2023: 3,824) |
| Customers with over 12 hours in the storm year 2019 | almost 100,000 |
The big spikes in the statistics are storm years: Gudrun in 2005, Per in 2007, Dagmar in 2011. Since Gudrun, the industry has replaced a lot of overhead line with underground cable and cleared power-line corridors, and since 2013 overhead lines above 25 kV must be protected against falling trees. Even so, rural networks running through forest are far more exposed than urban ones.
Two rules in the Swedish Electricity Act (ellagen) are worth knowing. Network operators must make sure an outage never exceeds 24 hours (the functional requirement), except where the cause is beyond their control. And for an uninterrupted outage of at least 12 hours you are entitled to outage compensation (avbrottsersättning): 12.5% of your estimated annual network charges for 12 to 24 hours, at least 2% of the price base amount (prisbasbelopp), plus another 25% for each further 24-hour period begun, capped at 300%. The Electricity Act is being replaced by a new law from 2027, so check the current rules then. The compensation will not pay for frozen pipes – the planning is still up to you.
For technical planning, this gives a simple three-tier model:
- Most outages last minutes to an hour. A small UPS or power bank covers that – as long as it is connected to the right devices.
- A few times in ten years it will be several hours. That calls for a battery of a few hundred watt-hours or an efficient DC set-up.
- After a severe storm, it can take days in the countryside. Then the ability to recharge (car, generator, solar panel) and strict priorities matter more than battery size.
Inventory: what your devices draw
Every runtime calculation starts with an honest list. Walk through the house and write down every device that is connected to the network or should keep running in an emergency. The table shows typical values for continuous operation. Individual devices can differ considerably – which is why the end of this section explains how to measure yourself.
| Device | Typical power | Energy per 24 h | Note |
|---|---|---|---|
| Fibre media converter (ONT) | 3–6 W | 70–145 Wh | almost always on a 12 V adapter |
| Wi-Fi router | 5–12 W | 120–290 Wh | example: FRITZ!Box 7530 AX, 6 W average according to the manufacturer |
| 4G/5G router | 5–15 W | 120–360 Wh | 5G and weak signal at the upper end |
| Small switch (5–8 ports) | 2–5 W | 50–120 Wh | without PoE |
| PoE switch, base load | 5–15 W | 120–360 Wh | plus the power of every device it feeds |
| PoE camera | 3–8 W | 70–190 Wh | example: UniFi G5 Bullet, max. 4 W; more at night with infrared |
| Wi-Fi access point / mesh node | 5–12 W | 120–290 Wh | Wi-Fi 6/7 towards the upper end |
| NAS with 2 drives | 5–15 W | 120–360 Wh | example: Synology DS224+, 4.4 W idle, 14.7 W in use |
| Recorder (NVR) with hard drive | 10–30 W | 240–720 Wh | the drive spins constantly with continuous recording |
| DECT or IP phone base | 1–3 W | 25–70 Wh | also needs the router |
| Alarm panel | 3–10 W | 70–240 Wh | usually with its own backup battery |
| Smart-home hub, mini PC | 3–15 W | 70–360 Wh | e.g. Home Assistant |
| Laptop while charging | 20–65 W | – | only intermittently |
| Smartphone | – | battery 15–20 Wh | energy in one full charge |
The “energy per 24 h” column is simply power times 24 hours. It is the number that really matters: batteries store energy (watt-hours), not power (watts).
Three typical set-ups
From the table come three loads that the rest of this guide works with:
| Set-up | Devices | Load | per 24 h |
|---|---|---|---|
| Basic connectivity | media converter 4 W, router with Wi-Fi 8 W | 12 W | 288 Wh |
| Household with cameras | basic connectivity, PoE switch 6 W, 2 cameras at 5 W, 1 mesh node 7 W | 35 W | 840 Wh |
| Small business | media converter 4 W, firewall/router 12 W, PoE switch 10 W, 4 cameras 20 W, 2 access points 16 W, NAS 15 W, IP phone 3 W | 80 W | 1,920 Wh |
The basic pattern is already visible: basic connectivity is cheap to protect. Every camera, every access point and above all a NAS with spinning drives multiplies the requirement.
Measure it yourself – properly
- Datasheets often quote maximum values. A camera rated “max. 8 W” may draw 4 W during the day. A router quoted at “12 W” averages half that. Calculating with maximum values is safe but expensive.
- Measure for 24 hours, not a moment. Cameras draw more at night with infrared; NAS drives sleep at night and spin up for backups. A plug-in energy meter (or a smart plug with metering) shows the watt-hours after 24 hours – exactly the number you need. I use Shelly smart plugs for this kind of measurement; they log consumption continuously.
- Cheap meters are inaccurate below 5 W. Measure a whole power strip with all the network gear together rather than each small device separately.
- Measure what will hang on the battery. If the router will later be fed directly with 12 V, the loss in its plug-in adapter disappears. The reading at the wall socket is therefore slightly high – which is fine.
Calculating runtime – step by step
The basic formula is simple:
Runtime in hours = usable energy in Wh ÷ power drawn from the battery in W
The difficulty lies in the two quantities in the formula. Usable energy is always less than the printed figure, and the power drawn from the battery is always more than what the devices consume. Let us take them one at a time.
Step 1: from amp-hours to watt-hours
Batteries are often rated in amp-hours (Ah) or milliamp-hours (mAh). You only get energy once you include the voltage:
Wh = Ah × volts
- 12 V lithium iron phosphate battery (LFP, nominal 12.8 V) with 100 Ah: 12.8 × 100 = 1,280 Wh.
- 12 V lead-acid battery with 7 Ah, as in many small UPS units: 12 × 7 = 84 Wh on paper.
- Power bank with 20,000 mAh: the figure refers to the voltage of the cells inside, usually 3.6–3.7 V, not the 5 V at the USB port. 20 Ah × 3.7 V = 74 Wh. Many power banks also print the watt-hours in small type – that is the honest number.
Step 2: how much of it is usable?
Several factors come off the nominal energy. They multiply:
| Factor | LFP battery | Lead-acid (UPS) | Power bank |
|---|---|---|---|
| Usable depth of discharge | 80–90% | 50% for long life, up to ~80% in an emergency | included in conversion loss |
| Voltage conversion | DC-DC 90–95%, inverter see below | built into the UPS | 75–85% of nominal energy reaches the USB port |
| Temperature | 0 °C: 80%, −20 °C: 50% (Victron datasheet) | much worse than at room temperature | lithium-ion similarly sensitive |
| Ageing | slow, still ≥ 80% after thousands of cycles | replacement often due after 3–5 years | depends on quality |
The power bank figures are well founded: the German consumer organisation Stiftung Warentest tested power banks in 2022; the weakest delivered the equivalent of 14,760 instead of the stated 20,100 mAh, just over 73%. Good models come close to 85%. Using 80% is realistic.
Step 3: how much does the load really draw from the battery?
This is the most common calculation error I see. There is almost always a converter between battery and device, and every converter costs energy:
- The devices' plug-in adapters: 80–90% efficiency, plus a small no-load consumption.
- Inverters (turning 12 V back into 230 V): 85–92% at moderate load, plus a fixed self-consumption that applies even with no load. A good small sine-wave inverter such as the Victron Phoenix 12/500 quotes about 6 W at no load; users have measured more, and basic models often draw considerably more.
- DC-DC converters (turning a fluctuating 11–14 V into a stable 12 V, or 12 V into the 48–54 V needed for PoE): 90–95%.
The inverter's fixed self-consumption is the main problem at small loads. An example from my own system: my hybrid inverter, which supplies the whole house, draws around 126 watts at idle (my own measurement) – it is fairly power-hungry; branded home battery systems are considerably more frugal, and for customer calculations I assume about 15 W including the battery management system (BMS). For a whole house during an outage that hardly matters. If you ran such a unit just for a 12-watt router, more than nine-tenths of the energy would go to the inverter itself. The measurements are in my case study of a price-controlled home battery.
Step 4: putting it together – a worked example
Take the “household with cameras” (35 W at the devices) and an LFP battery of 12.8 V and 100 Ah at room temperature.
- Nominal energy: 12.8 V × 100 Ah = 1,280 Wh.
- Usable at 80% depth of discharge: 1,280 × 0.8 = 1,024 Wh.
- Option A, via an inverter: the devices run on their plug-in adapters (85%) from an inverter (90%, 6 W at no load). Drawn from the battery: 35 ÷ 0.85 ÷ 0.9 + 6 = 45.8 + 6 = 51.8 W. Runtime: 1,024 ÷ 51.8 = about 20 hours.
- Option B, direct DC: router and media converter via a 12 V DC-DC converter (93%), PoE switch via a 48 V converter (90%). Combined about 91%: 35 ÷ 0.91 = 38.5 W. Runtime: 1,024 ÷ 38.5 = about 27 hours.
- Option A with a basic inverter (15 W at no load): 45.8 + 15 = 60.8 W, runtime about 17 hours.
The same battery therefore lasts 17 or 27 hours depending on how it is wired up. The difference costs nothing but a few suitable cables and converters. At −20 °C, say in an unheated equipment room, the usable energy halves: 512 Wh ÷ 38.5 W = just over 13 hours on DC.
Step 5: Peukert and the lead-acid battery
Lead-acid batteries deliver less energy the faster they are discharged – that is Peukert's law. How strong the effect is can be seen in APC's runtime table for the small Back-UPS BX750MI (750 VA). Converting the manufacturer's figures into watt-hours gives:
| Load | Runtime according to manufacturer | Energy delivered |
|---|---|---|
| 41 W | 50 min | about 34 Wh |
| 50 W | 42 min | about 35 Wh |
| 100 W | 20 min 27 s | about 34 Wh |
| 200 W | 7 min 33 s | about 25 Wh |
| 400 W | 1 min 50 s | about 12 Wh |
Three lessons follow. Such a typical small UPS delivers at best about 35 Wh – roughly a mid-size power bank. At high load, the energy collapses: at 400 W only a third comes out. And the figures apply to new, fully charged batteries at room temperature. After three years in a warm cupboard it can be considerably less. Below 41 W the manufacturer gives no figures; because the UPS itself draws power in battery mode, runtime does not rise proportionally at very small loads. Test it.
For LFP, Peukert is hardly an issue: at the loads in this guide (far below a tenth of rated capacity per hour), an LFP battery delivers practically all its energy.
Energy sources compared: UPS, power bank, LFP battery
With the three loads above and the factors from the previous section, these are realistic runtimes at room temperature:
| Energy source (usable) | Basic connectivity 12 W | Household with cameras 35 W | Small business 80 W |
|---|---|---|---|
| Small UPS 750 VA (~35 Wh) | 1–2 h (not stated by manufacturer, test) | just under 1 h | about 25 min |
| Power bank 20,000 mAh with 12 V output (~59 Wh) | 4–5 h | – | – |
| Portable power station 500 Wh (LFP, ~400 Wh via 230 V) | 15–20 h | 7–8 h | 3–4 h |
| LFP 12.8 V 100 Ah, DC (1,024 Wh) | about 3 days | about 27 h | about 11 h |
| LFP 12.8 V 100 Ah, inverter with 6 W idle | about 1.7 days | about 20 h | about 9 h |
| 2 × LFP 100 Ah, DC (2,048 Wh) | about 6 days | about 2 days | about 22 h |
This is how the figures come about, using basic connectivity on LFP and DC as an example: 12 W ÷ 0.93 = 12.9 W from the battery; 1,024 Wh ÷ 12.9 W = 79 hours, just over three days. With an inverter: 12 ÷ 0.85 ÷ 0.9 + 6 = 21.7 W; 1,024 ÷ 21.7 = 47 hours. Here the inverter costs more than a third of the runtime. For the power station I have assumed that 80% of the nominal energy is usable through the built-in inverter; check your model's no-load consumption, it is rarely printed on the box.
Which solution fits when
- UPS: essential for a NAS or small server so they shut down cleanly in an outage. It rides through flicker and short cuts with no interruption at all. For long outages it is the wrong choice, because its lead-acid battery is small and ages quickly.
- Power bank with 12 V output: the cheapest way to keep basic connectivity going for a few hours. Requirements: the media converter and router run on 12 V, and the power bank can supply 12 V via USB-C Power Delivery. Not all can – many offer only 5, 9, 15 and 20 V. A USB-C “trigger” cable requests the right voltage. Most power banks do not switch over seamlessly while a load is running; they are not a UPS replacement but something you plug in when needed.
- Mini DC UPS: a small battery pack with 12 V in and out that sits between adapter and router and takes over without interruption. Often the neatest solution for basic connectivity, though capacity is usually small. Use the printed watt-hour figure and 80%.
- Portable power station: a portable battery with mains sockets and USB. Convenient, often with LFP cells. Check whether it switches over automatically and quickly enough in an outage (some advertise a “UPS function”; the switchover time is in the datasheet) and how much the built-in inverter draws at idle. Many also have a 12 V output – use it for the router and media converter.
- LFP battery with charger: the solution for hours to days. Lithium iron phosphate is robust, handles many cycles and is safer than other lithium chemistries. You also need a suitable charger, a fuse close to the positive terminal, cables of adequate size and the converters.
- Home battery with backup (island) mode: if you have a hybrid inverter with backup output, the network gear simply runs on it. That is how it is set up at my place: the media converter and router are on the inverter's output and keep running from the battery when the grid fails. Installation and connection to the house wiring are work for an authorised electrician.
DC instead of an inverter: 12 V routers, PoE, USB-C
Almost all network equipment runs on DC internally. The plug-in adapter turns 230 V AC into 12 V DC. If you connect a battery through an inverter, you convert twice: from 12 V DC to 230 V AC, and back again in the adapter. Both steps cost energy, and the inverter keeps running even when almost nothing is drawn. Direct DC avoids all of that.
Step 1: read the labels
Look at the adapters for the media converter, router, switch and phone base. They show the output voltage, for example “12 V ⎓ 1.5 A”, and the connector (usually a 5.5 × 2.1 mm or 5.5 × 2.5 mm barrel plug). Note voltage, current and polarity (the symbol shows whether the centre pin is positive). Most media converters and many routers use 12 V. Some need 5 V (via USB), others 19–24 V.
Step 2: never connect the battery directly
A “12 V battery” is not 12 V. An LFP battery sits between roughly 12 and 13.4 V depending on charge, and up to 14.4–14.6 V while charging. A lead-acid battery can go just as high when charging. Many routers tolerate that; some do not. The safe option is a DC-DC converter with a regulated 12 V output (buck-boost), which turns anything from 10 to 15 V into a steady 12 V. It is cheap, 90–95% efficient and protects the devices.
Step 3: fuse it
An LFP battery can deliver hundreds of amps into a short circuit. That is why a fuse matched to the cable size belongs right at the positive terminal, and every branch to a device gets its own small fuse. Buy a battery with a built-in battery management system (BMS) that disconnects on under-voltage, over-voltage, over-temperature and – important in Sweden – cold while charging. Lead-acid batteries can give off hydrogen when charging and do not belong in a closed cupboard.
Step 4: PoE from the battery
Cameras and access points are usually powered over Ethernet. The IEEE 802.3af standard provides up to 15.4 W per switch port (12.95 W reaches the device), 802.3at up to 30 W (25.5 W at the device), and 802.3bt up to 60 or 90 W. PoE runs at roughly 44–57 V. From a 12 V battery there are three routes:
- PoE switch with DC input: some industrial and vehicle switches accept 12–48 V DC directly and generate the PoE voltage themselves. The cleanest solution for several cameras.
- Standard PoE switch with a 48–54 V adapter: many small PoE switches use an external 48–54 V adapter. A step-up converter from 12 to 48 V (or 52 V) replaces it. Match voltage and power to the original adapter.
- PoE injector with 12 V input: for a single camera or access point. Look for “active” PoE to 802.3af/at.
A warning: alongside the standard there is “passive PoE” with a fixed voltage (often 24 or 48 V) that puts power on the cable without checking the device. Only use passive PoE with devices that explicitly support it.
Step 5: USB-C for laptops, mini PCs and phones
USB-C Power Delivery has become a universal DC interface: laptops, tablets, phones, many mini PCs and some routers charge through it. A car charger or a 12 V USB-C adapter with Power Delivery connected to the battery replaces the plug-in adapter – again avoiding the detour via 230 V.
What you may do yourself – and what you may not
Plug-in devices, power banks, power stations, network cables and extra-low-voltage wiring between battery and devices are things a technically competent person can set up themselves. Care with fuses and cable sizes is still essential – an overloaded 12 V cable can catch fire. Anything permanently connected to the house's 230 V wiring, by contrast, is work for an authorised electrician (behörig elinstallatör): a changeover switch for a generator, a feed into the consumer unit, a hard-wired inverter. Without a correct changeover switch, a generator can feed power back into the grid and endanger line workers who believe the line is dead. What generators, power stations and home batteries with island mode can do, and how to connect them correctly, is covered in Backup power for home and cabin.
Priorities: what should run, and for how long?
The most expensive backup solution is the one that tries to keep everything running equally long. A tiered plan that decides what runs in which phase works better.
| Phase | Goal | What runs | How |
|---|---|---|---|
| The first minutes | nothing breaks, nothing is lost | everything, including NAS and server | UPS; NAS shuts down automatically after a set time |
| The first hours | stay reachable, keep an overview | media converter, router, one access point, the most important camera(s), phone base | DC supply or power station |
| From day one | stay in touch with minimal consumption | mobile phones, radio; router only at intervals | power banks, battery, recharging from car or generator |
Practical levers
- Shut the NAS down cleanly. Connect the UPS to the NAS via USB and set it to shut down after a few minutes on battery. Synology, QNAP and others support this out of the box, and several devices on one UPS can be controlled over the network. Once it is off, a NAS with spinning drives is also the biggest consumer gone.
- Choose your cameras. Not every camera matters in an outage. The one at the front door and the one in the barn perhaps; the one in the garden, no. Some PoE switches let you schedule ports or turn them off from an app.
- Run the router at intervals. If the mobile network is still up but the fibre is not, the router does not need to run continuously. Switching it on for half an hour twice a day is often enough to pick up messages.
- A second path instead of a bigger battery. A 4G/5G router with a SIM from a different operator than your phone, ideally with an outdoor antenna, keeps you connected when the fibre node goes dark. It draws 5–15 W – there is room for that in any battery plan. Many routers fail over automatically. What that looks like at a cabin without fibre is covered in Cameras at a holiday home without broadband and Cabin internet in Sweden.
- Save phone battery. Power-saving mode, screen brightness down, mobile data off when not needed. A smartphone often lasts two to three days that way.
Decision tree: which solution suits you?
- Do you have a NAS or server? Yes → UPS with shutdown signal, regardless of anything else.
- How long should the internet run?
- Up to 1 hour → a UPS for media converter and router is enough.
- 1 to 12 hours → mini DC UPS or power bank with 12 V output for basic connectivity; a power station if cameras should keep running too.
- Over 12 hours to days → LFP battery with DC distribution and a way to recharge.
- Does your fibre node have backup power? Ask your network owner or fibre association (fiberförening). Unknown or no → plan a second path via mobile; more battery for the fibre is wasted.
- Are you often away (cabin, business at weekends)? Yes → set up automatic alerts for power loss and battery level (see below).
- Is the building unheated in winter? Yes → battery and electronics in the warmest room, calculate with half capacity, LFP only with cold protection for charging.
Phone, 112 and alarms
The old landline is gone
The old copper telephone network powered the phones itself, which is why a corded phone kept working in a power cut. That network is being switched off during 2026. According to the Swedish Civil Defence and Resilience Agency (MCF, formerly MSB), traditional landline phones can then no longer be used. What is called a “landline” today runs over IP: the phone plugs into the router or into a base unit that calls over the mobile network. Both need mains power. Your landline number is therefore only reachable in an outage for as long as router, media converter and fibre node – or, for mobile-based solutions, base unit and mast – keep working. Ask your provider whether the unit has a battery and how long it lasts.
Mobile phones and 112
- A call to 112 is routed over any available mobile network, including another operator's (emergency roaming). If it does not connect, Krisinformation advises: restart the phone, remove the SIM card and dial 112 again. If nothing works at all: go to the nearest fire station, many have an emergency phone.
- The 2G and 3G networks are largely switched off: in 2025, Tele2 and Telenor closed 2G and 3G, and Telia and Tre closed 3G; Telia keeps 2G running until the end of 2027. Old phones, alarm units, personal alarms and gate controllers that only support 2G or 3G no longer work or soon will not.
- Have contracts with different operators within the family, or get a prepaid SIM from a second operator. If one network fails, another often still works. In a state of heightened alert (höjd beredskap), operators can also enable national roaming.
- From autumn 2026, public warnings (VMA) can be sent directly to phones via SE-Alert – which also needs a working mobile network.
How to stay reachable without power and fibre – with mobile networks, two-way radio and batteries – is covered in detail in Staying reachable in a power cut.
Alarm systems and sensors
Most alarm panels have their own backup battery that keeps the panel and wireless sensors running for a while. The weak point is rarely the panel but the transmission path: if the alarm reports via the router, it falls silent with the router. If it reports via its own SIM, it depends on the mast. Check in the manual how long the backup battery lasts according to the manufacturer, how old it is, and whether the system itself reports a power cut. The same goes for wireless sensors (temperature, water): they have their own batteries, but their hub needs power and internet.
How do you even know the power is off?
For a cabin or a business where nobody is present, the alert matters more than the runtime. A power cut you hear about two days later is a frozen pipe in winter. In my own system I have built the alert chain like this – the principles carry over to any solution:
- Detect: the controller checks the mains voltage on each of the three phases every few seconds. If one phase drops below a threshold, that counts as an outage – even if only one phase is missing (the cause can be the grid or your own main fuse), because the inverter switches to battery then too. A single garbled reading does not trigger anything; only two in a row.
- Alert via two paths: the message goes to my phone through two independent services. If one fails, the other gets through.
- Queue: in a power cut, the internet is often down too. Messages are therefore stored locally and delivered as soon as the connection returns – marked as delayed.
- Report the right number: the most important figure in an outage is not the charge level in per cent but the remaining runtime: usable energy down to the reserve divided by the current load. “14 hours left” is something you can decide on; “62%” is not.
- Remind: as long as the outage lasts, a new message with current values arrives every hour. When power returns: duration of the outage and energy used.
- The known gap: if the alerting device itself dies – battery empty, crash – nothing arrives. The remedy is a dead man's switch: the device checks in regularly with an external service, which raises the alarm when the check-ins stop. Without such a heartbeat, silence never means “all is well”.
Simpler ready-made solutions exist: many routers, UPS units with a network card, smart-home hubs and alarm systems report a mains failure via an app, provided they run on battery themselves and have a connection. In a cabin, a temperature sensor with an alarm below +5 °C is the single most important addition.
Norrland winter: cold, storms, ice
Most long outages in Norrland come with weather: storms, wet snow and ice load on trees and power lines. At the same time it is cold, and cold hits batteries twice.
- Capacity: according to the Victron datasheet, an LFP battery delivers 80% of its rated capacity at 0 °C and only 50% at −20 °C. Lead-acid batteries lose a lot too. The battery in an unheated garage or in the cabin's equipment cupboard has half when it counts.
- Charging: LFP must not be charged below roughly 0 °C; the Victron datasheet gives +5 °C to +50 °C as the charging range. A good BMS blocks charging in the cold – rightly so, but then the battery will not recharge after the outage either. Some batteries have built-in heating that first warms the cells using the charging current.
- Phones and power banks: lithium-ion cells drop off in the cold, and phones sometimes shut down at 30% charge in frost. Keep power banks indoors, not in the car.
- Location: put the battery and network gear in the room that stays warm longest during an outage. The devices' waste heat helps a little.
- Top up before the storm: SMHI warnings usually come a day ahead. Charge everything with a battery then. My own battery controller does this automatically: when SMHI issues a yellow or higher warning for wind, snow or rain, and when the forecast drops to −20 °C or below, it charges more generously, even at mid-range electricity prices, so the reserve is there during an outage. Otherwise it keeps about half of the capacity in reserve as a matter of course.
- Outdoor antennas and masts: ice and storms also hit your own equipment. Antennas, radio-link dishes and cameras on the gable should be mounted to carry snow and ice.
Scenarios: house, flat, cabin, off-grid, business, farm
Detached house with fibre
Typical equipment: media converter, router, one or two mesh nodes, two to four cameras, perhaps a NAS. Recommendation: basic connectivity (12 W) on a mini DC UPS or an LFP battery with a DC converter, the NAS on a small UPS with automatic shutdown, cameras by priority via a DC-powered PoE switch. Plus a 4G router as the second path. With a 100 Ah LFP battery, basic connectivity plus two cameras lasts about a day, basic connectivity alone about three days.
Flat or terraced house
In a block of flats, the operator's node often sits in the basement or an equipment room of the building. Whether it has backup power is known to the housing association (bostadsrättsförening) or landlord – or to no one. Without backup at the building node, the internet is gone the moment the power goes, whatever you do in your flat. Then power banks for the phones, a radio and mobile access are the right investment, not a large battery. Ask your association; a small UPS at the building node is often a very cheap improvement for all residents.
A cabin that is usually empty
Here it is about alerts, not comfort: when the power goes you want to know, and you want to see the temperature. The chain is: temperature and water sensors → hub or router → mobile network. Altogether that often draws 10–15 W. A 100 Ah LFP battery in the warmest room covers that in frost (half capacity) for about a day and a half – enough time to react. Many cabins have mobile rather than fibre anyway; then the mast is the limit. At my own holiday cabin, fibre, a 4G/5G router and a radio link are all in use, and the heating, temperature and water sensors can be monitored remotely. Several paths make monitoring more robust; how well they hold up in a power cut, though, depends above all on the power supply to the equipment at both ends.
Off-grid
Without a grid connection, the battery is the grid, and every watt of continuous load counts every single day. Network gear, cameras and fans belong in the energy budget. The case study of an off-grid cabin near Sundsvall shows what that looks like in practice, with two mobile operators as a redundant connection.
Small business
Till, card terminal, phones, cameras, server or NAS. The card terminal is the sensitive point: on Wi-Fi it goes down with the router; a terminal with its own SIM depends on the mast. For a shop with 80 W of network load, two 100 Ah LFP batteries on DC last just under a day. More important than runtime is often a clear routine: who shuts down what, how do you take cash or charge later, who informs customers. On card terminals, see Card terminal keeps losing connection.
Farm with livestock
On a farm, the milking system, ventilation, water pump and heating are the real backup loads, and they need a generator with a properly installed changeover switch – a job for the electrician. The IT part is small but important: barn camera, calving camera, alarm on ventilation failure. That chain should be backed up separately with a battery so it also covers the minutes before the generator starts, and a generator that stops. On cameras in the barn, see the calving camera guide.
How to test: the planned power cut
Backup power that has never been tested is a guess. A test takes an hour and almost always reveals something nobody had thought of.
- Prepare: fully charge all batteries. Note which devices hang on which battery. Tell your family or staff. Note the time.
- Simulate the outage: switch off the power strip that the UPS or charger is plugged into rather than pulling the plug – that keeps the earth connected. If you want to test the whole house, switch off the main switch; remember the freezer, heat pump and aquarium.
- First minute: does everything keep running without interruption? If a device reboots, it is not on the UPS, or the switchover is too slow.
- Check reachability: can you reach cameras and router from your phone (over mobile, not your own Wi-Fi)? Did the “power cut” alert arrive?
- Read the consumption: the UPS, power station or battery monitor shows the load in watts. Does it match your calculation?
- NAS shutdown: does the NAS shut down cleanly after the set time?
- Test the second path: additionally unplug the fibre from the media converter. Does the router switch to mobile? Do alerts still arrive?
- Let it run: for an hour, and note the charge level. From that you can extrapolate the real runtime – more accurately than any table.
- Switch back: power on again. Does everything come back by itself? Does the all-clear arrive? Does the battery recharge?
- Record: date, load, runtime, anything unusual. Compare at the next test – if runtime is falling, the battery is ageing.
| Test record | Entry |
|---|---|
| Date, time, outdoor temperature | |
| Load in W as displayed | |
| Charge level at start / after 60 min | |
| Extrapolated runtime | |
| Devices that rebooted | |
| Did the alert arrive? After how many minutes? | |
| Did the NAS shut down cleanly? | |
| Did failover to mobile work? | |
| Actions |
What does it cost?
Equipment prices vary a lot; the examples below are from Swedish shops and price comparison sites in October 2026 and are only meant to show the order of magnitude:
- Small 750 VA UPS (e.g. APC Back-UPS BX750MI): about SEK 1,350. A replacement battery after a few years comes on top.
- LFP battery 12 V, 100 Ah: on price comparison sites about SEK 2,000–3,300 for budget brands and about SEK 7,000–7,500 for brand-name batteries such as Victron. Add a charger, fuses, cables and converters.
- Power banks and small parts such as DC-DC converters, trigger cables and barrel-plug adapters cost hundreds rather than thousands of kronor each.
The biggest cost is rarely the hardware but choosing the right parts and a set-up that actually works when it counts. My work is charged at SEK 1,000 per hour; on site in your home, the RUT deduction (50%) applies to work on routers, networks and computers if you are taxed in Sweden; cameras, alarms and remote help do not qualify.
Fixed-price packages
- Check Power cut network – SEK 1,500. About 1.5 hours, network, phone and cameras only: what depends on what, how long it lasts, what is missing. SEK 750 after RUT for the part covering router and network; cameras do not qualify for RUT.
- Setup Backup communication & alarm – SEK 3,500 labour plus hardware. 12 V supply or UPS for router and converter, backup internet, alarms via two paths, a heartbeat check and a joint test.
Private customers pay including VAT, businesses and farms excluding VAT. Travel within Medelpad is included. The price of a check is credited if you then order a setup. The RUT deduction applies to work on routers, networks and computers – shown separately on the invoice – but not to alarms, cameras, smart home or remote support. Work on the fixed house wiring is done by an authorised electrician.
Common mistakes
- Router on the UPS, media converter not. The router runs, but without a fibre signal. A classic.
- The PoE switch is forgotten. The cameras hang on the switch, the switch on an ordinary socket.
- UPS battery never replaced. The display says “battery OK” until the first real outage.
- An inverter for 15 W. The idle draw eats a large part of the battery.
- Battery in a cold room. Half the capacity is missing, and it cannot recharge.
- Flat power bank. It has been in a drawer since last summer.
- Second path via the same mast. Phone and 4G router with the same operator – if the mast fails, both are gone.
- Alerts via the line that just went down. The alarm e-mail arrives when the power is long back.
- Old 3G equipment. An alarm unit or personal alarm that has been silent since 2025 without anyone noticing.
- Battery straight to the router. 14.6 V while charging is too much for some 12 V devices.
- No fuse at the positive terminal. An LFP battery delivers enough current into a short circuit to start a cable fire.
- Never tested. See above.
Maintenance: what to check and when
| When | What |
|---|---|
| Monthly | UPS self-test (most units can do this via a button or software); check the display for warnings |
| Every 3 months | Recharge power banks and power station (lithium holds charge well but self-discharges slowly); is the paper phone list up to date? |
| Yearly, in autumn | Full test as described above; check battery ages; inspect cables and fuses; top up the prepaid SIM or check its validity |
| After 3–5 years | Replace the UPS lead-acid battery, sooner if the test shows clearly shorter runtimes |
| Whenever something changes | New device on the network? Measure its consumption and update the runtime calculation |
Printable checklist
Inventory
- All network devices listed with voltage, connector and consumption
- Consumption measured over 24 hours (Wh per day)
- Asked the network owner or fibre association: does our fibre node have backup power, and for how long?
- Alarm system: transmission path and backup battery checked, no 2G/3G equipment left
Backup power
- Media converter and router and (PoE) switch on backup power
- NAS on a UPS with automatic shutdown
- DC instead of an inverter wherever possible; DC-DC converter with stable output
- Fuse at the positive terminal, correct cable sizes
- Battery in the warmest room, cold-weather capacity allowed for
- Second internet path via a different operator
Communication
- Charged power banks, at least one per person
- Car charger for phones in the car
- Battery, solar or wind-up radio for Sveriges Radio P4
- Important numbers on paper: family, network operator, neighbours, vet, employer
- Nearest fire station and the municipality's support point (trygghetspunkt) known
- 113 13 for information, 112 in an emergency
Alerts and testing
- Power-cut alert to your phone set up and tested
- Temperature sensor with alarm (cabin)
- Annual test in autumn, test record filled in
If you want to think bigger – generator, heating, water, supplies – the basics are on MCF's home preparedness pages (Hemberedskap), on krisinformation.se, which also has information in English, and put into practice in the technical preparedness checklist. For the network side, this list has everything in one place.
Frequently asked questions
How long does fibre internet work in a power cut?
Without your own battery, not at all – the media converter and router need power. With a battery, for as long as the operator's fibre node has backup power. Small nodes with fewer than 2,000 connections had no minimum even under the PTS rules that applied until January 2026. Ask your network owner or fibre association.
How long do mobile masts last?
Under the PTS regulation in force until 14 January 2026, masts had to last at least 1 hour in towns of over 8,000 people and 4 hours elsewhere. The regulation was repealed with the new Cybersecurity Act and successor rules are being drafted. The sites were built to those values; plan for hours, not days.
Is a UPS enough for the router?
For short outages, yes. A typical small 750 VA UPS delivers about 35 watt-hours according to the manufacturer's table. That keeps the media converter and router going for one to two hours, or about an hour with cameras. For longer outages, a power bank with a 12 V output or an LFP battery on DC is far more efficient.
Can I run my router from a power bank?
Yes, if the router uses 12 V and the power bank can supply 12 V via USB-C Power Delivery. A trigger cable requests the voltage. A 20,000 mAh power bank (74 Wh) powers a media converter and router drawing 12 W together for about four to five hours. It will not switch over seamlessly like a UPS, though.
Why not use an inverter for network equipment?
Because it converts twice (12 V to 230 V and back in the adapter) and draws power even with no load. At small loads that costs a quarter to over a third of the runtime. Routers, media converters and switches run on DC internally and can be fed directly from the battery via DC-DC converters.
Will my landline work in a power cut?
The old copper network, which powered phones itself, is being switched off during 2026. Today's landline service runs via the router or a base unit on the mobile network and needs mains power. Without a battery, your landline number is gone the moment the power goes.
How does cold affect the battery?
According to the Victron datasheet, an LFP battery delivers 80% of its capacity at 0 °C and only 50% at −20 °C, and should only be charged from about +5 °C. Put batteries in the warmest room and assume half capacity in unheated buildings.
Do I get compensation for a long power cut?
Yes. Under the Swedish Electricity Act you are entitled to outage compensation after at least 12 hours without interruption: 12.5% of your estimated annual network charges (at least 2% of the price base amount), 25% more for each further 24-hour period begun, capped at 300%. A new law applies from 2027; check the rules then.
May I connect a backup battery myself?
Plug-in devices and extra-low-voltage wiring between battery and network equipment can be set up by a technically competent person, with a fuse and the right cables. Anything permanently connected to the house's 230 V wiring – generator changeover switch, feed-in, hard-wired inverter – must be done by an authorised electrician.
No affiliate links. Recommendations are based purely on hands-on experience.
Want to know how long your network, cameras and phone will really last in an outage? With the Check Power cut network (SEK 1,500 incl. VAT, SEK 750 after RUT for router and network) I list all devices, measure their consumption, check your backup power and give you a runtime calculation with a concrete shopping list. I am happy to set up the DC supply, NAS shutdown, alerts and test in the Setup Backup communication & alarm (SEK 3,500 plus hardware) and credit the check against it. On site in Medelpad (travel included), otherwise remotely – in English, German or Swedish.
Network and Wi-Fi in Sundsvall Book a free callExternal sources:
- PTS – PTSFS 2022:11, ch. 11 §§ 8–10 (backup power, in force until 14 Jan 2026)
- PTS – impact assessment, repeal of the security regulations on 15 Jan 2026
- PTS – guidance on secure electronic communication services (PTS-ER-2024:23)
- PTS – incident and supervision report 2024
- PTS – pilot project: hydrogen backup power for mobile sites
- PTS – shutdown of the 2G and 3G networks
- Energy Markets Inspectorate – supply reliability in Sweden's grids 2024 (Ei R2025:17)
- Electricity Act (1997:857) – functional requirement and outage compensation
- MCF – access to communication in a crisis (reviewed 1 Oct 2026, Swedish)
- Krisinformation – if the internet and telephone services go down
- Swedish National Electrical Safety Board – during a power cut (Swedish)
- Victron – datasheet 12.8 V LFP batteries (capacity in the cold, charging temperature)
- APC/Schneider Electric – runtime table Back-UPS 750 VA
- Stiftung Warentest – power bank test (2022, German)
- FRITZ! – FRITZ!Box 7530 AX, specifications
- Ubiquiti – UniFi G5 Bullet, specifications
- Synology – DS224+, specifications
- Inet – APC Back-UPS 750 VA (price Oct 2026)
- PriceRunner – 12 V 100 Ah LFP batteries (prices Oct 2026)