First check: is consumption really too high?
Comparing with the neighbours tells you little: different house, different insulation, different habits. What matters are your own figures. Every electricity meter in Sweden records at least hourly, and your grid company shows the values free of charge under “Mina sidor” (my pages). With a contract such as Tibber you also see them in the app.
Look for three things:
- Compare equally cold weeks. A January week at −25 °C uses several times as much as a week at −2 °C. Comparing month with month without looking at the outdoor temperature leads to the wrong conclusions.
- Look for jumps. The compressor runs steadily and usually modulates its output smoothly. The electric backup heater, by contrast, switches in steps of several kilowatts. Hourly values that suddenly sit 3, 6 or 9 kWh higher on a mild night are a strong hint.
- Look inside the heat pump itself. Many units show operating hours or energy split between compressor and backup heater (often under “Driftinfo”, “Drifttid” or “Energiförbrukning” on Swedish menus). If the backup heater runs when it is above freezing, something is wrong.
Mistake 1: the backup heater kicks in too often
Almost every air-to-water, exhaust-air and ground-source heat pump has a built-in electric immersion heater. It is meant for the coldest days and as a reserve. But every kilowatt-hour it delivers costs you a full kilowatt-hour of electricity – the compressor produces several times as much heat from the same electricity. That is why a backup heater running more than necessary is the largest single item on the bill.
Typical causes:
- The start threshold is too tight. Many units add up how long and how far the flow temperature has been below target – NIBE calls this “degree minutes”. Once a limit is passed, the heater joins in. If that limit is too close to the compressor’s start threshold, the heater switches on before the compressor has had a chance to catch up.
- The permitted output is higher than needed. If the heater is allowed its highest step, it will use it, even though a lower one would often do.
- Extra hot water or “Lux” left on permanently. These modes are meant for an evening with guests. Left on, they make the heater help out regularly.
- After a power cut or a service visit the unit is sometimes back on factory settings or in a mode where only the backup heater heats.
Important: on an air-to-water heat pump it is normal for the heater to help during hard frost – that is how it is designed. Switching it off completely is not a good idea: on the coldest days the house gets cold or the water no longer gets hot enough. The goal is for it to run only when the compressor genuinely cannot cope.
Mistake 2: the heating curve is too high
The heating curve sets how warm the water flowing to the radiators or underfloor heating is, depending on the outdoor temperature. The higher this flow temperature, the harder the compressor has to work and the lower its efficiency. The manufacturer Thermia gives a rule of thumb: one degree lower indoor temperature saves about 5% of heating energy, and with a heat pump up to around 10% if you lower the curve on the pump instead of turning down the radiator valves.
A common vicious circle: the radiator thermostats are half closed, the house does not get warm enough, so the curve is turned up. The pump now heats at a higher temperature against throttled valves. Do it the other way round:
- Open the radiator thermostats fully in the main rooms (bedrooms and rarely used rooms may stay throttled).
- Lower the curve in small steps, one step or one degree at a time.
- Wait one to two days after each change. A house reacts slowly, underfloor heating even more slowly.
- Tell the cases apart: too warm in mild weather but fine in frost – shift the whole curve down (offset). Too cold only in frost – the curve needs a steeper slope, not a higher base level.
Mistake 3: a sensor measures in the wrong place
The heat pump follows what its sensors report. If a sensor is badly placed, it regulates perfectly – towards the wrong value.
- Outdoor sensor in the sun: on a south- or west-facing wall the pump “sees” above-zero temperatures on a clear winter day and heats too little. The curve then gets turned up – and at night and on grey days it is too warm. The sensor belongs on a shaded north- or north-east-facing wall, not above a window, door or ventilation outlet.
- Room sensor next to the wood stove or in a sunny window: the pump thinks the whole house is warm and throttles back. The other rooms get cold and the curve gets raised. Conversely, a room sensor in a cold hallway overheats the rest of the house.
- Air-to-air heat pump: the indoor unit usually measures the temperature at the unit itself, up near the ceiling where the air is warmest. The temperature on the remote control is therefore not the room temperature. Many models can use the sensor in the remote control instead – if it lies in the room and not in a drawer.
Mistake 4: hot water too hot or reheated too often
Hot water costs a heat pump more than space heating, because it needs higher temperatures. From around 55–60 °C the compressor in many units can no longer manage alone, and the electric heater does the rest.
At the same time there is a lower limit you should not go below: under Boverket’s building rules, hot water must reach at least 50 °C at the tap, and in a circulation loop it must not drop below 50 °C anywhere – because of legionella. At the tap it should be no more than 60 °C, to prevent scalding.
What you can check:
- Legionella cycle (often “periodisk förhöjning” or “legionellaskydd”): it periodically heats the tank to a high temperature, usually with the electric heater. Once a week is a common interval. If it is set to daily, it costs money for nothing. Do not switch it off without talking to your installer.
- Time of day: with an hourly or quarter-hourly price, the cycle should run at night or in a cheap period, not at 5 pm.
- Comfort level: “Normal” or “Economy” is enough for many households. “Lux” all the time is expensive.
- Circulation: a hot water circulation loop running around the clock loses heat constantly and has to be reheated. Whether it can be put on a timer depends on the installation – because of the 50 °C rule, that is a question for the installer.
Mistake 5: night setback as with the old oil boiler
With an oil or wood boiler, turning the heating down at night saved fuel. With a heat pump the maths often does not work: in the morning the house is supposed to warm up quickly, the pump needs a higher flow temperature for that – and that is exactly when the backup heater likes to kick in. With underfloor heating a setback hardly ever pays, because the floor is far too slow.
Better: an even temperature and a correctly set curve. A small setback of one or two degrees can work with radiators if the warm-up starts gently. If you control the pump by electricity price, shift in small steps too, not big jumps. How that works with Tibber or Home Assistant is explained in Controlling a heat pump with Tibber or Home Assistant. In a holiday home that stands empty for days, on the other hand, a clearly lower maintenance temperature makes sense – many air-to-air units have a dedicated mode around 8–10 °C. More in Multi-split heat pump in the cabin.
Mistake 6: defrosting and a snowed-in outdoor unit
Air-source heat pumps regularly defrost their outdoor unit because frost forms on the fins. That is normal and happens especially often in humid air around 0 °C – not unusual along the Norrland coast. During defrosting the pump delivers no heat but uses energy.
It becomes too much when the outdoor unit is badly placed:
- It stands directly on the ground instead of on a stand and gets snowed in.
- Snow slides off the roof onto it, or it sits in a corner where snow drifts in.
- Meltwater cannot drain away and freezes into a block of ice under the unit.
- Leaves, pollen or dirt clog the fins and restrict the airflow.
Keep the outdoor unit clear and the airways open. If it still stays heavily iced up, or defrosts constantly even in dry cold, call the installer – it may point to a sensor fault or a problem in the refrigerant circuit.
Mistake 7: clogged filters
- Air-to-air heat pump: the filters in the indoor unit clog quickly during the heating season, faster still with pets. The unit delivers less heat for the same electricity. Vacuum them or tap them out gently, roughly once a month.
- Exhaust-air heat pump (very common in Swedish houses): if the exhaust air filter is full, the pump gets less warm air to extract heat from – and the electric heater makes up the difference. Change the filter as the manufacturer specifies, often several times a year.
- On the water side: a dirty strainer in the heating circuit or air in the radiators reduces the flow. The pump then raises the flow temperature to get enough heat into the house anyway.
Measuring consumption: three ways
| Method | What you see | Effort |
|---|---|---|
| Hourly values from the grid company | Whole-house consumption per hour, usually from the next day | free, just log in to “Mina sidor” |
| Tibber Pulse on the meter | Whole-house consumption in real time; the backup heater’s jumps are visible immediately | The meter’s HAN port is closed by default; the grid company has to open it (can take a few days) |
| A meter just for the heat pump, e.g. Shelly with current clamps | The heat pump’s own consumption, separate from the rest of the house | Installed in the consumer unit – in Sweden only a registered electrical installation company may do that |
You learn most when these values end up in one overview together with the outdoor temperature, for example in Home Assistant. Then you see at a glance: consumption jumps by 6 kW every morning at 6 – that is the night setback, not the cold. How I evaluate my own installation with Tibber and Home Assistant is described in the case study on the price-controlled home battery.
Checklist to work through yourself
- All current settings photographed before you change anything
- Hourly values from the grid company or the Tibber app checked for one mild and one cold week
- Operating hours or energy of the backup heater read from the menu and compared with the compressor
- Backup heater does not run above freezing
- “Extra hot water”, “Lux” or similar comfort functions not permanently on
- Legionella cycle at most weekly and at a cheap time of day
- Hot water at least 50 °C at the tap, but no hotter than needed
- Radiator thermostats open in the main rooms, heating curve lowered in small steps
- Outdoor sensor on a shaded north- or north-east-facing wall, not above a window or vent
- Room sensor not next to a wood stove, radiator or sunny window
- No deep night setback, none at all with underfloor heating
- Outdoor unit on a stand, free of snow and ice, meltwater can drain
- Filters (indoor unit, exhaust air, strainer) clean
- One change at a time, then one to two days of observation
When the installer has to step in
Recurring error messages, an outdoor unit that stays iced up, unusual noises, falling pressure in the heating circuit or the brine: these are jobs for a certified refrigeration technician. Only certified technicians may work on the refrigerant circuit. I do not install or repair heat pumps myself, but I can put you in touch with a certified installer.
How I can help
My part is everything to do with figures, settings and control. With the energy check at a fixed price of 500 SEK I analyse your consumption with the real prices in your electricity area and tell you whether it stands out and where the kilowatt-hours go. With the Check Heat pump at a fixed price of 1,500 SEK (about 1.5 hours) we also go through the settings together by video call, photos or the app – heating curve, backup heater, hot water and legionella cycle, setback, sensors. You get a written recommendation with concrete values, and after two to three weeks we look together at what it achieved. All of it works remotely, in English, Swedish or German. If you then want to measure the pump or control it by electricity price, I set that up in Home Assistant and credit the price of the check. Both prices incl. VAT, no RUT (remote work).
Frequently asked questions
How much electricity is normal for a heat pump?
It depends on the house, insulation, type of pump and the winter, so a general figure does not help much. More telling is a comparison with your own values from equally cold weeks – and the share used by the backup heater. If it runs above freezing, consumption is too high.
Can I simply switch off the legionella cycle?
Not without asking your installer. Hot water must reach at least 50 °C at the tap, and the cycle makes sure legionella does not multiply in the tank. It usually makes sense to set it to once a week and to a cheap time of day.
Does a night setback pay off with a heat pump?
Usually not, or only a little. When the house warms up again in the morning, the pump needs a higher flow temperature and the backup heater often kicks in. With underfloor heating, skip it; with radiators, lower by one or two degrees at most.
Can I break something by changing the settings?
Hardly in the user menu, as long as you photograph the old values and change only one thing at a time. Only touch the service or installer menu with guidance. Work on the refrigerant circuit is always a job for a certified installer.