Why is my heat pump using so much electricity? The common settings mistakes

The first winter bill after the new heat pump is higher than expected, or consumption creeps up year after year. Usually the heat pump is not broken but badly set: it heats with its built-in electric heater instead of the compressor, makes the hot water hotter than it needs to be, or works against a sensor sitting in the sun. You can find most of these mistakes yourself – if you know where to look.

In short: The three most expensive mistakes are almost always the same: the electric backup heater (in Swedish an “elpatron”) kicks in too often, the heating curve is set too high, and the hot water is heated hotter or more often than necessary. Measure first, then change one setting at a time – and take a photo of the old values before you touch anything.

First check: is consumption really too high?

Comparing with the neighbours tells you little: different house, different insulation, different habits. What matters are your own figures. Every electricity meter in Sweden records at least hourly, and your grid company shows the values free of charge under “Mina sidor” (my pages). With a contract such as Tibber you also see them in the app.

Look for three things:

Mistake 1: the backup heater kicks in too often

Almost every air-to-water, exhaust-air and ground-source heat pump has a built-in electric immersion heater. It is meant for the coldest days and as a reserve. But every kilowatt-hour it delivers costs you a full kilowatt-hour of electricity – the compressor produces several times as much heat from the same electricity. That is why a backup heater running more than necessary is the largest single item on the bill.

Typical causes:

Important: on an air-to-water heat pump it is normal for the heater to help during hard frost – that is how it is designed. Switching it off completely is not a good idea: on the coldest days the house gets cold or the water no longer gets hot enough. The goal is for it to run only when the compressor genuinely cannot cope.

Mistake 2: the heating curve is too high

The heating curve sets how warm the water flowing to the radiators or underfloor heating is, depending on the outdoor temperature. The higher this flow temperature, the harder the compressor has to work and the lower its efficiency. The manufacturer Thermia gives a rule of thumb: one degree lower indoor temperature saves about 5% of heating energy, and with a heat pump up to around 10% if you lower the curve on the pump instead of turning down the radiator valves.

A common vicious circle: the radiator thermostats are half closed, the house does not get warm enough, so the curve is turned up. The pump now heats at a higher temperature against throttled valves. Do it the other way round:

  1. Open the radiator thermostats fully in the main rooms (bedrooms and rarely used rooms may stay throttled).
  2. Lower the curve in small steps, one step or one degree at a time.
  3. Wait one to two days after each change. A house reacts slowly, underfloor heating even more slowly.
  4. Tell the cases apart: too warm in mild weather but fine in frost – shift the whole curve down (offset). Too cold only in frost – the curve needs a steeper slope, not a higher base level.

Mistake 3: a sensor measures in the wrong place

The heat pump follows what its sensors report. If a sensor is badly placed, it regulates perfectly – towards the wrong value.

Mistake 4: hot water too hot or reheated too often

Hot water costs a heat pump more than space heating, because it needs higher temperatures. From around 55–60 °C the compressor in many units can no longer manage alone, and the electric heater does the rest.

At the same time there is a lower limit you should not go below: under Boverket’s building rules, hot water must reach at least 50 °C at the tap, and in a circulation loop it must not drop below 50 °C anywhere – because of legionella. At the tap it should be no more than 60 °C, to prevent scalding.

What you can check:

Mistake 5: night setback as with the old oil boiler

With an oil or wood boiler, turning the heating down at night saved fuel. With a heat pump the maths often does not work: in the morning the house is supposed to warm up quickly, the pump needs a higher flow temperature for that – and that is exactly when the backup heater likes to kick in. With underfloor heating a setback hardly ever pays, because the floor is far too slow.

Better: an even temperature and a correctly set curve. A small setback of one or two degrees can work with radiators if the warm-up starts gently. If you control the pump by electricity price, shift in small steps too, not big jumps. How that works with Tibber or Home Assistant is explained in Controlling a heat pump with Tibber or Home Assistant. In a holiday home that stands empty for days, on the other hand, a clearly lower maintenance temperature makes sense – many air-to-air units have a dedicated mode around 8–10 °C. More in Multi-split heat pump in the cabin.

Mistake 6: defrosting and a snowed-in outdoor unit

Air-source heat pumps regularly defrost their outdoor unit because frost forms on the fins. That is normal and happens especially often in humid air around 0 °C – not unusual along the Norrland coast. During defrosting the pump delivers no heat but uses energy.

It becomes too much when the outdoor unit is badly placed:

Keep the outdoor unit clear and the airways open. If it still stays heavily iced up, or defrosts constantly even in dry cold, call the installer – it may point to a sensor fault or a problem in the refrigerant circuit.

Mistake 7: clogged filters

Measuring consumption: three ways

MethodWhat you seeEffort
Hourly values from the grid companyWhole-house consumption per hour, usually from the next dayfree, just log in to “Mina sidor”
Tibber Pulse on the meterWhole-house consumption in real time; the backup heater’s jumps are visible immediatelyThe meter’s HAN port is closed by default; the grid company has to open it (can take a few days)
A meter just for the heat pump, e.g. Shelly with current clampsThe heat pump’s own consumption, separate from the rest of the houseInstalled in the consumer unit – in Sweden only a registered electrical installation company may do that

You learn most when these values end up in one overview together with the outdoor temperature, for example in Home Assistant. Then you see at a glance: consumption jumps by 6 kW every morning at 6 – that is the night setback, not the cold. How I evaluate my own installation with Tibber and Home Assistant is described in the case study on the price-controlled home battery.

Checklist to work through yourself

When the installer has to step in

Recurring error messages, an outdoor unit that stays iced up, unusual noises, falling pressure in the heating circuit or the brine: these are jobs for a certified refrigeration technician. Only certified technicians may work on the refrigerant circuit. I do not install or repair heat pumps myself, but I can put you in touch with a certified installer.

How I can help

My part is everything to do with figures, settings and control. With the energy check at a fixed price of 500 SEK I analyse your consumption with the real prices in your electricity area and tell you whether it stands out and where the kilowatt-hours go. With the Check Heat pump at a fixed price of 1,500 SEK (about 1.5 hours) we also go through the settings together by video call, photos or the app – heating curve, backup heater, hot water and legionella cycle, setback, sensors. You get a written recommendation with concrete values, and after two to three weeks we look together at what it achieved. All of it works remotely, in English, Swedish or German. If you then want to measure the pump or control it by electricity price, I set that up in Home Assistant and credit the price of the check. Both prices incl. VAT, no RUT (remote work).

Frequently asked questions

How much electricity is normal for a heat pump?
It depends on the house, insulation, type of pump and the winter, so a general figure does not help much. More telling is a comparison with your own values from equally cold weeks – and the share used by the backup heater. If it runs above freezing, consumption is too high.

Can I simply switch off the legionella cycle?
Not without asking your installer. Hot water must reach at least 50 °C at the tap, and the cycle makes sure legionella does not multiply in the tank. It usually makes sense to set it to once a week and to a cheap time of day.

Does a night setback pay off with a heat pump?
Usually not, or only a little. When the house warms up again in the morning, the pump needs a higher flow temperature and the backup heater often kicks in. With underfloor heating, skip it; with radiators, lower by one or two degrees at most.

Can I break something by changing the settings?
Hardly in the user menu, as long as you photograph the old values and change only one thing at a time. Only touch the service or installer menu with guidance. Work on the refrigerant circuit is always a job for a certified installer.