Why the cold changes the maths
A heat pump moves heat from a cold source into the house. The bigger the temperature gap between source and heating system, the more electricity it needs per kilowatt-hour of heat. This is expressed as COP (efficiency at a given moment) and SCOP (seasonal average over a year). A COP of 3 means 1 kWh of electricity gives 3 kWh of heat.
With ground source, the source is bedrock 100 to 200 metres down. It stays a few degrees above zero all year – even when it is −30 °C outside. With air-to-air and air-to-water, the source is the outdoor air, and both output and efficiency fall as it gets colder. The Swedish Energy Agency (Energimyndigheten) says so plainly: air-source heat pumps work less well in northern Sweden, and it describes air-to-water as suitable for houses in southern Sweden.
That does not make air-source heat pumps pointless up here. It means the coldest third of the winter decides the economics, not the average temperature.
What happens at −30 °C?
| System | At −30 °C | What takes over |
|---|---|---|
| Ground source | Runs as normal; the source is as warm as in October. The house does, however, need more output than the pump is sized for. | Built-in immersion heater (elpatron) for the peak |
| Air-to-water | Nordic models are often rated for operation down to −25 to −35 °C (check the data sheet), but then deliver much less heat at low efficiency. | Immersion heater in the indoor unit or hot water tank |
| Air-to-air | Many units keep running, but with little output; some switch off the compressor in severe frost. | Your existing panel heaters |
The house will not get cold – the backup heater steps in. But those hours are expensive, and they often coincide with the highest electricity prices and the highest load. If your grid company charges a capacity fee (effektavgift), or you only have a 16 A main fuse, work this out before you choose a system.
SCOP: read the right line on the energy label
Under EU energy-labelling rules, seasonal efficiency is calculated for three climate zones: warmer, average and colder. The big number in the brochure almost always refers to the average climate, roughly central Europe. For northern Sweden, the value that matters is the one for the colder climate – it appears on the product fiche, or on the label for air-to-air units. If it is missing, ask the seller why.
Bear in mind that the label SCOP only covers space heating at a specific flow temperature. Hot water and backup heating are not included. My worked example therefore uses cautious annual figures for the whole system, including hot water and backup.
Manufacturer figure or field measurement: which numbers I use
The figure in the brochure comes from a test rig under standard conditions. Independent field measurements in occupied homes regularly find considerably lower values:
- Lokale Agenda 21 Lahr (Germany, 2006–2013): an independent working group metered 52 heating heat pumps with heat and electricity meters. The air source heat pumps in the first phase averaged a seasonal performance factor (SPF) of 2.8, and none of the 13 exceeded 3.0; ground-coupled systems averaged between 3.1 and 3.4. The authors' conclusion: there are considerable differences between test-rig figures and seasonal performance under realistic operating conditions.
- SP (now RISE) for the Swedish Energy Agency: 20 ground source heat pumps in Swedish detached houses built between 1940 and 1979 were measured for two years. The SPF ranged from 1.9 to 3.6, averaging 2.7 in the colder year and 2.9 in the milder one.
- Fraunhofer ISE: even more recent field tests in renovated older houses in Germany – a much milder climate than northern Sweden – found average SPFs between 2.5 and 3.4 for air-to-water heat pumps (interim result 2017, 15 systems).
Brochures for the same types of unit often quote 4 or more. Not all of these measurements are new, and the technology has improved – but the gap between test rig and family home remains, especially in cold weather, with high flow temperatures and lots of hot water. That is why I calculate with real-world figures rather than manufacturer claims, and I recommend you do the same.
What that means in kronor is shown for the example house from the worked example further down (20,000 kWh heat demand, 1.50 SEK per kWh):
| System | Calculated with brochure figure | Calculated with field figure | Extra cost per year |
|---|---|---|---|
| Ground source | SPF 4.5: 4,440 kWh, about 6,700 SEK | SPF 2.9: 6,900 kWh, about 10,300 SEK | about 3,700 SEK |
| Air-to-water | SPF 4.0: 5,000 kWh, about 7,500 SEK | SPF 2.8: 7,140 kWh, about 10,700 SEK | about 3,200 SEK |
The brochure figures are example assumptions; the field figures are the averages from the measurements above. Over 15 years the difference for ground source adds up to around 55,000 SEK – enough to overturn a payback calculation. My worked example below therefore uses values in line with the field measurements: 3.0 for ground source and, because of the cold in northern Sweden, only 2.3 for air-to-water.
What the house needs
- Ground source and air-to-water require water-based heating: radiators or underfloor heating with pipes. Many Swedish houses, however, are heated with electric panel heaters (direktverkande el). A water-based system must then be installed first – often the biggest cost item.
- A low flow temperature improves efficiency. Underfloor heating or large radiators are ideal; small radiators sized for a 70 °C oil boiler may need replacing or supplementing.
- Ground source needs permission to drill: space for the borehole, distance to neighbours' wells and sewage systems, and a notification to the municipality. In Sundsvall the borehole is notified to the environmental office (miljökontoret), and you may not start until you have written confirmation. The fee equals 1.5 hours of processing (2026 rate: 1,465 SEK per hour, so about 2,200 SEK).
- Air-to-air works best in open-plan houses. Every closed door is a wall for the warm air. Your tap water is still heated by the electric water heater.
- Outdoor units of air-source pumps need a stand above snow level, protection from snow and icicles falling off the roof, and a drain for defrost water that does not freeze up. Sounds trivial, but it is a common cause of winter trouble up here.
Investment and savings – a worked example
The example is a typical 1970s house in the Sundsvall area. Every figure is an assumption you should replace with your own:
- Heat demand 20,000 kWh a year: 16,000 kWh space heating, 4,000 kWh hot water.
- All-in electricity price (energy, supplier margin, grid fee, energy tax, VAT): 1.50 SEK per kWh. Check against your own bill.
- Today, with electric panel heaters: 20,000 kWh × 1.50 SEK = 30,000 SEK a year.
| System | Assumption | Electricity afterwards | Saving per year | Investment (market range) |
|---|---|---|---|---|
| Air-to-air | covers half the space heating, seasonal factor 2.5 | 15,200 kWh | about 7,200 SEK | 18,000–32,000 SEK installed, after ROT |
| Air-to-water | seasonal factor 2.3 for the whole system | 8,700 kWh | about 17,000 SEK | 90,000–180,000 SEK complete |
| Ground source | seasonal factor 3.0 for the whole system | 6,700 kWh | about 20,000 SEK | 180,000–280,000 SEK incl. drilling |
The price ranges come from Swedish price guides for 2026 (sources below) and vary widely with the house, borehole depth and installer. For air-to-water and ground source they assume the house already has water-based heating.
That gives payback times of roughly:
- Air-to-air: 25,000 SEK / 7,200 SEK = about 3.5 years.
- Air-to-water: 140,000 SEK minus ROT 12,600 SEK = 127,400 SEK / 17,000 SEK = about 7.5 years.
- Ground source: 230,000 SEK minus ROT 24,150 SEK = 205,850 SEK / 20,000 SEK = about 10 years.
In this example ground source takes longest to pay back, but it gives the largest annual saving, depends least on cold January nights, and the borehole lasts for decades. The higher the heat demand, the faster it pays off. In a small house using 10,000 kWh a year, the saving rarely justifies a borehole.
If a house with panel heaters first has to be converted to water-based heating, you are in a different league. In one example the Swedish Energy Agency assumes 266,000 SEK for water-based heating plus an air-to-water heat pump – about 1,800 SEK per square metre. In that case air-to-air, possibly combined with a heat pump water heater, is often the most economical option.
The ROT deduction: 30 per cent of labour
Installing a heat pump qualifies for the ROT deduction, and so does drilling for ground source. Since 1 January 2026 the deduction is back at 30 per cent of labour costs (the temporary increase to 50 per cent only applied in 2025), up to 50,000 SEK per person per year. For a fixed-price turnkey contract the installer may calculate labour using the Swedish Tax Agency's standard rate: 35 per cent of the total for ground source and drilling, 30 per cent for air-source heat pumps. The deduction therefore works out at about 10.5 and 9 per cent of the total price respectively.
You must be taxed in Sweden and pay enough tax to use the deduction, and own the house and live in it or use it as a holiday home. The green technology tax reduction does not cover heat pumps – only solar panels, battery storage and EV chargers. Details, and what the quote must contain: see the guide on replacing an oil boiler or electric heating.
Decision matrix
| Your house | Sensible first choice | Why |
|---|---|---|
| Panel heaters, open plan, limited budget | Air-to-air | Short payback, heaters stay as backup |
| Panel heaters, high heat demand, staying long-term | Cost out water-based heating + ground source | Large investment, biggest long-term saving |
| Water-based heating with oil, electric or wood boiler, drilling possible | Ground source | Steady efficiency even at −30 °C, hot water included |
| Water-based heating, drilling not possible | Air-to-water (Nordic model), or ground loop on a large plot | Works, but expect more backup heating in winter |
| House with mechanical exhaust ventilation | Exhaust air heat pump, possibly supplemented | Indoor air is a steady heat source |
| Small house or low demand (below about 10,000 kWh) | Air-to-air or air-to-water | Ground source rarely pays back |
| Holiday home kept just above freezing | Air-to-air with maintenance heat mode | Low investment, remote control possible |
Checklist before you request quotes
- Find your consumption: annual use from your bills, and ideally hourly data from your grid company's customer portal (Mina sidor). It shows how much goes into heating in winter.
- Note your main fuse size and large loads (cooker, sauna, EV charger).
- Check the heating system: panel heaters, water-based, radiator size, underfloor heating.
- Ask for the colder-climate SCOP, the minimum operating temperature and heat output at −15 and −25 °C.
- Ask for the sizing: what share of annual heat the pump covers and how much the backup heater is expected to run.
- Choose an installer certified for refrigerants. According to the Swedish Environmental Protection Agency this is a legal requirement, even for an air-to-air unit.
Where I can help
I do not sell or install heat pumps – certified installers do that. I help before and after: analysing your consumption with real prices, costing the options, reviewing quotes and, if needed, helping you find a certified installer. In English, even if the installer only speaks Swedish. Afterwards the heat pump can be linked to Home Assistant or Tibber so it heats water when electricity is cheap. Your municipality's free energy and climate advice service (energi- och klimatrådgivning) is also a good first step – impartial, but without a detailed calculation for your house, and usually in Swedish.
Frequently asked questions
Does an air-to-water heat pump work in Sundsvall?
Yes, but it loses output and efficiency in severe frost, and the immersion heater covers a larger share of the winter. Choose a Nordic model and compare the colder-climate SCOP.
Can an air-to-air heat pump replace all panel heaters?
Rarely. It mainly heats the rooms the air reaches and does not heat tap water. Keep the heaters as a supplement and backup in severe cold.
Are there grants for heat pumps in Sweden?
The green technology tax reduction does not cover heat pumps. What you can get is the ROT deduction: 30 per cent of labour costs, if you are taxed in Sweden.
Do I need a permit for ground source heating?
In Sundsvall the installation must be notified to the environmental office before drilling, and work may only start after written confirmation. Other municipalities have similar rules.
No affiliate links. Recommendations are based purely on hands-on experience.
Not sure which system suits your house? With the Plan Heat pump at a fixed price of 3,500 SEK incl. VAT (about 3.5 hours) I analyse your consumption, cost two or three options and review up to three installer quotes – in English. You can also start with the 500 SEK energy check. I do not install myself, but I help you find a certified installer.
Energy check and smart energy control Book a free callExternal sources:
- Lokale Agenda 21 Lahr (Auer/Schote): heat pump field test 2006–2013, final report (German)
- SP/Swedish Energy Agency (Haglund Stignor et al., 2015): field measurements of 20 ground source heat pumps
- Fraunhofer ISE: heat pump field tests in existing buildings (press release 2017, German)
- Swedish Energy Agency: Choosing a heat pump (Swedish)
- Swedish Energy Agency: Example savings calculations (Swedish)
- Swedish Tax Agency: ROT work and standard labour rates (Swedish)
- Swedish Tax Agency: Green technology tax reduction (Swedish)
- Sundsvall Municipality: Heat pump notification (Swedish)
- Swedish EPA: Use certified staff for heat pump installation (Swedish)
- EU Regulation 811/2013 on energy labelling (three climate zones)
- Bygghemma: Air-source heat pump and installation prices (Swedish)
- Offerta: Cost of an air-to-water heat pump (Swedish)
- Boio: Heat pumps for houses 2026 (Swedish)