The idea: the house as heat storage
A heat pump cannot make the heat demand disappear, but it can shift it in time. If it heats a little extra in cheap hours and backs off in expensive ones, the house acts as a store. How well that works depends on how much thermal mass the house has:
- Heavy house: concrete slab with underfloor heating, masonry walls, lots of mass. Temperature changes slowly – good for shifting heat over several hours.
- Light house: the typical Swedish timber house with radiators, or a cabin with an air-to-air heat pump. It cools quickly once the heat stops, so pauses must be short.
- The hot water tank is the easiest store: it can heat up when power is cheap. But the water must reach at least 50 °C at the tap to prevent legionella (Swedish building rules), so it cannot wait indefinitely.
Test it yourself: on a cold evening, switch the heating off for three hours and log the indoor temperature. If it drops only a few tenths of a degree, you have good storage. If it drops a full degree within the first hour, the house is too light for long pauses.
Two things eat into the gain: when catching up, the heat pump runs at a higher flow temperature and therefore lower efficiency, and a warmer house loses more heat. So the gain per shifted kilowatt-hour is always less than the price difference.
How do you connect the heat pump?
| Interface | Suits | Pros | Cons |
|---|---|---|---|
| Manufacturer cloud (app/API) | many newer units, e.g. NIBE, Daikin, Mitsubishi, Panasonic | no extra hardware | depends on cloud and internet; some services cap requests per day or require a paid subscription |
| Modbus (local) | larger air-to-water and ground-source heat pumps, sometimes as an accessory | stable, fast, works without internet | needs the right model or accessory, more setup |
| Infrared (e.g. Sensibo) | air-to-air heat pumps with a remote | simple, works with almost all | one-way – the unit does not confirm; needs line of sight |
| Sensor/thermostat offset | water-based systems | works with most brands | coarse, only steers via the “weather” the pump thinks it sees |
| SG Ready input | many newer heat pumps | manufacturer’s own block/boost modes | only a few steps; wiring into the heat pump is done by an authorised installer |
The last option is often underrated: the heat pump knows best how to respond and does not switch on the immersion heater unnecessarily.
Tibber or Home Assistant?
Tibber’s smart heating is the easy route: connect, configure, done. But support depends on the model. For NIBE you need an S-series heat pump and a NIBE room sensor; without the sensor you can only monitor temperatures. CTC heat pumps currently have no smart heating control via Tibber. Air-to-air heat pumps are controlled through an IR device such as Sensibo.
Home Assistant takes more work but lets you set your own rules: minimum indoor temperature, a lock on the immersion heater, weather forecasts, and coordination with a battery and EV charging so that everything does not start in the same quarter hour. Prices come from Tibber or directly from the power exchange. I run a battery myself that charges by the quarter-hour price using Tibber and Home Assistant – the case study shows the measured result, including what the losses cost.
What does it realistically save?
The most thorough Swedish figure I have found comes from a master’s thesis at Lund University (2026). It simulated an air-to-water heat pump in a house in southern Sweden with dynamic electricity prices and four control strategies:
- With comfort maintained: at most 820 SEK per year.
- Without comfort requirements: around 1,340 SEK per year, roughly 6% of the household’s electricity cost – with clearly reduced comfort.
In northern Sweden (SE2) daily price swings are usually smaller than in the south, so savings there are likely lower. Smart thermostat providers often quote higher percentages, but these usually include lower temperatures and better basic settings – not just price control.
A rough calculation of my own: a heat pump using 6,000 kWh of electricity a year. If a third can be shifted to hours that are 30 öre cheaper, that is 2,000 kWh × 0.30 SEK = 600 SEK – before the losses mentioned above. That fits the study well.
Compare that with the basic settings: according to the Swedish Energy Agency’s rule of thumb, each degree lower indoors cuts energy use by about 5%. A heating curve set too high or an immersion heater kicking in unnecessarily often costs more than price control will ever earn.
The comfort traps
- The immersion heater makes up for the pause. The biggest trap. After a long pause the house lags behind and the heat pump switches on its auxiliary heater. That heats at an efficiency of 1 instead of 3 – and the whole gain is gone. Fix: short pauses, a lock or a higher start threshold for the auxiliary heater.
- Power peaks. If your grid operator charges a capacity fee, a heat pump that starts at full power when the price drops can cause an expensive peak – especially if the car is charging at the same time.
- Hot water runs out for a late shower if the tank had to wait too long.
- Underfloor heating reacts slowly both ways – cold floors in the morning may be yesterday’s control decision.
- The cloud is down or the request limit is reached: the heat pump must then fall back to normal operation on its own and never get stuck in “pause”.
- The family. A control nobody understands that makes the house cold soon gets switched off. Better a little less saving and a house that is always warm.
The right order
- Measure: hourly values from your grid operator or Tibber show what the heat pump and immersion heater actually use.
- Get the basics right: heating curve, auxiliary heat, hot water, night setback – see the most common settings mistakes.
- Then add price control – carefully, with a minimum temperature and a lock on auxiliary heat, and review after a few weeks.
I do not install heat pumps and do not touch the refrigerant circuit. I help with measurement, settings and control – and can put you in touch with a certified installer if something needs doing on the pump itself. More on the page smart energy control with Home Assistant.
Frequently asked questions
How much does controlling a heat pump by electricity price save?
According to a Lund University study (2026), at most around 820 SEK a year if comfort is to be maintained – in southern Sweden. In SE2 price swings are usually smaller. Better basic settings often save more.
Does Tibber smart heating work with my heat pump?
It depends on the model. NIBE needs the S-series and a NIBE room sensor, CTC is currently not supported, and air-to-air heat pumps run via an IR device such as Sensibo. Check Tibber’s list for your model.
Do I need Home Assistant?
No, for simple price control Tibber is enough if your pump is supported. Home Assistant is worth it for your own rules, locking the immersion heater or coordinating heat pump, battery and EV.
Can price control make my bill higher?
Yes, if the immersion heater makes up for the pauses or if peaks occur with a grid operator that charges a capacity fee. Hence: short pauses, a lock on auxiliary heat and a review after a few weeks.
No affiliate links. Recommendations are based purely on hands-on experience.
Want to know whether price control pays off in your house? Start with an energy check at a fixed price of 500 SEK: I review your consumption and settings. After that I connect your heat pump to Home Assistant or Tibber with the Setup Heat pump control (3,500 SEK incl. VAT, hardware extra) – with locks that protect your comfort. If you do not have Home Assistant yet, its basic setup adds 1,500 SEK. Control systems count as smart home and do not qualify for RUT. In English, remotely or on site.
Smart energy control with Home Assistant Book a free callExternal sources:
- Jolde & Gross (2026): Ekonomisk analys av styrstrategier för värmepump i villa, Lund University (Swedish)
- Tibber: NIBE myUplink + Tibber, requirements (Swedish)
- Tibber: CTC + Tibber (Swedish)
- Tibber: Sensibo Air Pro, IR control (Swedish)
- Boverket: legionella – hot water temperature requirements (Swedish)
- Thermia (2025): electricity price and heat pumps – 1 degree ≈ 5% rule of thumb per the Swedish Energy Agency (Swedish)