First: what needs to work out there?
The technology follows the need. A few typical cases:
- Attefall house (“attefallshus”) for guests or letting: Wi-Fi for phones, streaming on the TV, perhaps a guest network kept separate from your own.
- Garage or carport: EV charger, a camera at the driveway, app-connected tools, the occasional laptop.
- Workshop or office: a desk with video calls, machine controls, cameras, backups to the NAS in the house.
Bandwidth is rarely the issue – almost every option below delivers more than an outbuilding needs. What matters is stability (cameras and chargers should not drop off three times a day), maintenance, and whether the link survives a storm, a thunderstorm and a northern Swedish winter.
The options at a glance
| Option | Sensible distance | Strengths | Limits |
|---|---|---|---|
| Wi-Fi from the house / mesh | a few metres up to approx. 20–30 m with line of sight | no digging, quick to set up | outer walls attenuate, every wireless hop shares airtime, weather-dependent |
| Outdoor AP on the house + AP in the outbuilding | up to approx. 50 m with line of sight | much better than mesh through a wall | still Wi-Fi, channel shared with other devices |
| Point-to-point wireless link | from a few metres to over a kilometre | no digging, dedicated radio link, high throughput | needs clear line of sight, mounting points, power at both ends |
| Copper network cable in the ground | max. 100 m incl. patch leads | cheap material, PoE possible | lightning and potential differences between buildings |
| Fibre in a buried duct | up to several kilometres | electrically isolated, robust, future-proof | needs a trench, converters or SFP ports at both ends |
Wi-Fi and mesh: where the limit is
A mesh system whose satellite in the guest house only talks to the house wirelessly sometimes works surprisingly well – and sometimes not at all. Three things decide:
- The walls: timber attenuates little. Modern windows with metal coatings, foil-faced insulation, render on metal mesh and sheet-metal cladding attenuate a lot. The signal has to pass two outer walls – the house’s and the outbuilding’s.
- Wireless hops: when the satellite relays data on the same band it uses to serve devices, it shares airtime. The result is noticeably lower throughput and uneven latency.
- Weather: wet leaves, snow on branches, hoarfrost on antennas – what works in July can wobble in January.
Much better than mesh through a wall: an outdoor access point on the house, wired back to the network and aimed at the outbuilding, plus an access point inside the outbuilding. For a guest house 15 metres away, that is often the simplest good solution.
Copper in the ground: 100 metres and the lightning problem
A copper network cable is the obvious idea: cheap, PoE-capable, a switch at each end. Two limits are worth knowing:
- 100 metres is the maximum length of an Ethernet run, including the patch leads at both ends. Beyond that the link becomes unstable or does not come up at all.
- Two buildings, two reference points: each building has its own earthing. A lightning strike nearby – not only a direct hit – can cause brief, large voltage differences between the buildings. A long copper cable between them becomes the path for that current. Typical damage: switch or network ports dead at both ends, sometimes the connected device too.
For a garage a few metres from the house that is fed from the house’s supply, copper is common and acceptable with surge protection at both ends (properly earthed – that is the electrician’s job). For longer distances, buildings with their own grid connection or exposed locations, fibre is the safe choice.
If you use copper, do it properly: outdoor cable with a PE jacket rated for burial or ducts, solid copper rather than cheap CCA, and always in a protective duct. An ordinary indoor PVC cable will not last long in damp soil.
Fibre between buildings
Fibre does not conduct electricity. That takes lightning and potential differences between buildings out of the equation, and distance too, for practical purposes: single-mode fibre runs for several kilometres. At each end you need either a media converter (fibre to network cable) or a switch with an SFP port and a matching module.
For a domestic plot there are pre-terminated outdoor fibre cables with connectors and a pulling sleeve – they are pulled through the duct, and no splicing is needed. What matters is a large enough duct, no tight bends (fibre does not tolerate a small bend radius) and clean connectors. For new installations I recommend single-mode (OS2), because it covers any future speed and distance.
Wireless links: when digging is too expensive or impossible
Two directional antennas aimed at each other create their own radio link – not Wi-Fi, but a separate connection with a focused beam. It is reliable when the conditions are right:
- Clear line of sight between the antennas, and not just as a line: the so-called Fresnel zone, an ellipse-shaped space around the direct path, should be largely clear. Trees attenuate, especially at 5 GHz and with wet leaves or snow load.
- Solid mounting points on a gable, mast or wall – a mast that sways in a storm loses alignment.
- Power at both ends, usually PoE from each building.
What this looks like in practice is described in a case study on this site (in German and Swedish) about my own property in Stöde: 300 metres between house and workshop, a trenching quote of 120,000 SEK, connected instead by a wireless link for around 24,000 SEK. For short distances the equipment is far cheaper: simple 5 GHz point-to-point units cost a few hundred kronor each from Nordic retailers. The work is then mainly mounting, alignment and integrating the link into the network.
If you dig: everything in one trench
The trench is usually the most expensive part – so dig only once. If you are building an Attefall house or running power to the garage for an EV charger, the trench is happening anyway. Then it should take:
- The power cable – laid by the electrician. Laying cable in the ground is electrical installation work in Sweden and may only be done by a registered electrical installation company. Depth, protective duct and spacing for the mains cable are set by the electrician according to the applicable requirements.
- Two data ducts: one for the fibre, one spare. An empty duct with a draw wire costs next to nothing and saves you if a cable gets damaged or something is added later.
- Spacing between power and data as specified by the electrician, with warning tape above.
- Pull pits or access points at changes of direction and on long runs.
- Seal the duct ends and lay the duct so water does not collect – water in a duct freezes in winter.
- Document it: photos of the open trench with a tape measure, position measured from the house in a sketch.
Whether the main fuse can take an extra EV charger in the garage is for the electrician to work out – what matters is covered in EV charger, heat pump, solar: planning the main fuse and consumer unit.
Before digging: cables and pipes owned by utilities can be looked up free of charge through Ledningskollen. Your own cables on the plot – to the pump, the garden lights, the robot mower – exist only in your own records. How deep the data duct should be depends on terrain and use; network owners often require a few decimetres for their fibre on private land. Under a driveway that is driven on, it needs to go deeper and in a sturdier duct.
What does each option cost?
| Option | Materials | Network labour (1,000 SEK/h) | Trench |
|---|---|---|---|
| Outdoor AP + AP in the outbuilding | two access points, cable on the house | approx. 2–4 h | no |
| Wireless link, short distance | two radio units, brackets | approx. 3–5 h | no |
| Copper in a duct (up to 100 m) | outdoor cable (roughly 9–10 SEK/m at Swedish retail), surge protection | approx. 2–4 h | yes |
| Fibre in a duct | pre-terminated outdoor cable, two converters or SFP modules | approx. 2–4 h | yes |
The hours are typical figures for the network work, excluding digging and electrical work. Trenching costs vary enormously: a few metres through lawn is very different from 300 metres through forest, roots and across a stream as in the Stöde example. That is why the comparison matters: if you are digging for power anyway, fibre is the best option for the smallest extra cost. If you would be digging only for the network, a wireless link is often cheaper.
ROT and RUT
- Burying cable on the plot does not qualify for RUT according to Skatteverket, but may count as ROT work (30% of labour).
- No ROT for new construction: building an outbuilding, including a detached Attefall house, does not qualify for ROT. For conversions, the five-year rule from the house’s completion year applies.
- Network in the home: a network with cables and sockets in or close to the home qualifies for RUT (50% of labour). Garages and storerooms count as part of the home for a detached house. Farm buildings on agricultural property do not. In borderline cases – such as an Attefall house that is let out – ask Skatteverket in advance.
- Materials, travel, cameras and alarms never qualify for RUT. More in IT help at home and the RUT deduction.
Checklist
- Need defined: guest Wi-Fi, desk, cameras, EV charger, machines?
- Distance measured (cable route, not as the crow flies) – over 100 m, no copper
- Line of sight checked, including in winter with snow on the trees
- Power in the outbuilding? Its own connection or fed from the house?
- Digging anyway? Plan electrician, fibre and spare duct together
- Fibre rather than copper between separate buildings
- Duct ends sealed, warning tape, photos and sketch of the open trench
- A spot in the outbuilding for a switch or converter, with a power socket
Frequently asked questions
Is a mesh satellite in the guest house enough?
Sometimes, over short distances with walls that attenuate little. More stable is an outdoor access point on the house wired to the network, or a cable or point-to-point link.
Can I bury an ordinary network cable to the garage?
No. Use outdoor cable rated for burial or ducts, always in a protective duct, 100 metres at most. Between separate buildings, fibre is the safer choice because of lightning and potential differences.
Can I dig the trench and lay the cables myself?
You may dig yourself. The power cable in the ground, however, must be laid by a registered electrical installation company. Data ducts and fibre are low voltage – agree depth and spacing with the electrician.
When is a wireless link better than digging?
When you would be digging only for the network, the distance is long or the terrain difficult, and there is clear line of sight. If you are digging for power anyway, fibre in the same trench is usually the better choice.
No affiliate links. Recommendations are based purely on hands-on experience.
Want to connect an outbuilding? For this there is the Check plus Outbuilding at a fixed price of 2,500 SEK (about 2.5 hours, private customers incl. VAT, travel within Medelpad included). I look at distance, line of sight, existing ducts and power supply on site (appointment by arrangement) and recommend cable, fibre or a wireless link in writing – with a materials and cost range and notes for the electrician if there will be digging. If we then build the link, the check is credited. In English, Swedish or German, reply within 24 hours.
Network cabling in Sundsvall Book a free callExternal sources:
- Skatteverket – Ger arbetet rätt till rutavdrag? (Swedish)
- Skatteverket – Så fungerar rotavdraget (Swedish)
- Elsäkerhetsverket – Vad får jag göra själv med el? (Swedish)
- Ledningskollen (PTS) – look up buried utilities before digging
- Example price, outdoor Cat6 cable (Electrokit, October 2026)
- Example prices, 5 GHz point-to-point units (Prisjakt Norway, October 2026)